Securel v2
Technical Support:
8
3
LED NOTIFICATION
The programming LED will notify the
programming mode
, the
pairing mode
and the
lock status
.
If the device is not paired, it will be in
pairing mode
and this will be notified by a
blue
flicker
.
On the other hand, if the device is paired, the relay status will be notified with
the LED
green lighted if the relay is closed
(door opened). The LED
turn off when the relay
gets open
(door closed).
When the
programming mode
is activated, only this mode will be notified by
lighting
the LED in red
.
Note
:
Securel v2 can be paired or open/close the relay while the programming mode is
active, but only the programming mode is notified (i.e., the LED remains lighting in red)
.
A long press
(longer than three seconds)
will always activate the pairing mode
,
regardless of if the programming mode is active or not (if it is active, is deactivated).
In short, the different states that are notified are:
Programming mode:
Red LED ON
.
Pairing mode (Securel v2 not paired):
B
l
u
e
L
E
D
b
l
i
n
k
i
n
g
.
Relay Status (Securel v2 paired):
➢
Open (door closed): Green LED off.
➢
Closed (door opened):
Green LED on
.