General notes

 

 Read these instructions carefully right up to the 
end!

 

 Water meters are precision instruments. Protect 
against shock and vibration. Store frost-free.

 

 The sealing surface and thread is equipped with 
protection cap.

 

 Check and ensure before beginning the instal-
lation:

• 

 That the sealing surfaces are flat and free from 

damage such as notches, grooves, etc.

• 

That all indications on the dial are readable.

• 

 The meter fits in type, size, temperature and 

pressure rating to the installation and metering 
point.

 

 For polluted water we recommend installing of a 

filter or strainer in the inlet; before the meter is 

be installed.

 

 The meter should always be installed at the lo-
west possible point of the piping as well as frost 
protected, to prevent the accumulation of air and 
damages.

 

 The water meter must be installed into the pipe-
line free of any of mechanical forces or tensions.

 

 Water meters must be operating completely filled 

with water - for wet dial meters this includes also 
the counter!

 

 The meter must be protected with appropriate 
measures against pressure shocks in the pipe-
line.

 

 In case of frost empty completely and shut off the 

installation (including the meter), if necessary, 
dismount the meter.

 

 The meter must always be easily accessible and 
legible. The dial and the indications regarding the 
conformity/metrology must be visible and reada-
ble at any time.

 

 We recommend that the installation points on the 
pipeline should be secured with a seal against 

unauthorized  dismounting. The  seal  should  not 

be removable or loosened without visible dama-
ge.

 

 The installation has to be done by qualified pro

-

fessional personnel.

Installation:

1. 

 Close valves upstream and downstream of the 
meter.

2. 

Release pressure at the installation point.

3. 

Dismount existing meters or meter blanks.

4. 

Use only new and flawless sealing material.

5. 

Check the sealing surfaces for damage.

6. 

 Ensure that the seals don‘t fall out during instal-
lation.

7. 

 Screw in the meter by hand and tighten it with a 
suitable installation wrench.

8. 

 

Open valves carefully and avoid pressure 
shocks.

9. 

Check installation for leakage.

Declaration of conformity

ZENNER International GmbH & Co. KG declares 
that the product with the number of the EC type-

examination  certificates  DE-17-MI001-PTB005, 
CH-MI001-10040  or  CH-MI001-14062  complies 

with the essential requirements of the EC directive 

2014/32/EU (Measuring instruments directive).

ZENNER International GmbH & Co. KG hereby de-

clares that the product for Remote Metering RDM 

with the application Wireless Communications 
complies with the essential requirements of the EC 

directive 1999/5/CE (R&TTE).

The declaration of conformity and the latest in-
formation about this product can be accessed or 
downloaded from 

www.zenner.com

 Français

 English

Subject

 to

 modifications

 and

 errors

 excepted.

 Any

 liability

 for

 misprints

 excluded.

 

Отзывы: