10
Dimensions
IMF-ST
Dimensions
IMF-FA
Español
Italiano
Français
English
Deutsch
Technical data flow sensor model IMF-ST, IMF-FA
Nominal flow
q
p
m³/h
3.5
3.5
6
6
6
10
10
Nominal diameter
DN
mm
25
25
25
25
32
40
40
inch
1
1
1
1
1 ¼
1 ½
1 ½
Overall length without
connectors
L2
mm
135
150
135
150
150
150
200
Length with connectors
approx.
L1
mm
253
268
253
268
274
278
328
Thread meter G x B
D1
inch
1 ¼
1 ¼
1 ¼
1 ¼
1 ½
2
2
Thread connector R x
D2
inch
1
1
1
1
1 ¼
1 ½
1 ½
Metrological class
Standard class 2, optionally 3 according to EN 1434
Installation position
horizontal (the register always has to face upwards)
Pulse value
l/pulse
10
10
10
10
10
10
10
Cable length
m
1,5 / 3 (it will be extendable by 7 m)
Maximum flow
q
s
m³/h
7
7
12
12
12
20
20
Minimum flow *
q
i
m³/h
0.14
0.14
0.12/
0.24
0.12/
0.24
0.12/
0.24
0.2/
0.4
0.2/
0.4
Temperature range
°C
5 °C ≤ Θq ≤ 120 °C
Nominal pressure
PN/PS
bar
16
Ambient conditions /
climatic influencing
- climatic
Highest permissible ambient temperature 55 °C
Lowest permissible ambient temperature 5 °C
Protection class IP65
- metrological
class
M2
- elektromagnetic
class
E2
Pressure loss at q
p
bar
≤ 0,25
Heat carrier
Water
glycol (without Declaration of conformity)
Height
H1
mm
195
195
195
195
195
206 (ST)
197 (FA)
231 (ST)
212 (FA)
Width
B
mm
95
95
95
95
95
110
110
Weight
kg
3.1
3.1
3.1
3.1
3.1
5.5
5.5
* optionally
Содержание IMF
Страница 27: ...27...