background image

Operation

6

Installation

Polymer enters the PEP-II pump on the
suction side where shaft rotation exposes
gear tooth volumes between the gear
teeth. Polymer fills these spaces and is
transported to the discharge side where
the gear teeth mesh together, decreasing
the gear tooth volumes and displacing the
polymer. Due to the precision tolerances
and close clearances within the rotating
spaces, very high pressures can be
achieved at the pump discharge with
extremely high volumetric efficiencies.

As PEP-II pumps rely on the metered

polymer for lubrication of internal bearing
surfaces, the operating speed is designed
to be from 10 to 90 rpm on most extrusion
processes depending on process parame-
ters.

Do not allow the pump to run dry

or attempt to pump poor lubricating 

fluids such as water or solvent.

When

high-viscosity fluids are used, more time
is required to fill the tooth volumes. As a
result, the inlet pressure must be
increased or the gears must rotate at a
slower speed to ensure complete volume
filling. Proper speed and inlet pressure
must always be maintained to prevent
cavitation and to ensure proper lubrication.

Slip can occur across the sides 

of the gears from the high-pressure side
to the low-pressure side. The amount of
slip depends on four factors: polymer 
viscosity, speed, differential pressure 
and pump clearances. Under reasonably
stable operating conditions, slip is repeat-
able and predictable, and pump operation
can be adjusted to compensate.

Pumps should be carefully unpacked to
make sure that the shipment is complete.
If any items are missing or damaged, the
freight carrier and Zenith should be noti-
fied immediately.  

To prepare the pump for use:

1) Where required, install the heat

plates as follows. Zenith-supplied heat
plates are machined to tolerances that
eliminate the need for heat transfer cement.
All bolts used should be lubricated with
high-temperature thread lubricant such 
as DAG Dispersion 154, Felpro C-100 or
equivalent.

2) Place the top heat plate on the

pump, then place the insulation jacket on
top of the heat plate. Install and tighten
the bolts, taking care not to crack the
insulation block.

3) Repeat for the bottom plate, noting

that bottom heat plate mounting bolts are
typically used to mount the pump to its
mounting block.

4) Place the supplied metal O-rings

into the counterbores in the pump ports,
and attach the inlet and discharge porting
flanges with lubricated screws. Replace
the O-rings after each use. Torque down
the screws in a crisscross pattern, taking
them first to 1/4 the recommended torque
value, then to 1/2, to 3/4 and finally to
their full recommended torque value as
shown on the table on page 10. If the
flanges are not supplied by Zenith, make

certain that their mating faces are flat,
with no pilots that protrude into the pump.
Check that the pump rotates freely by
turning the shaft with your hand.

5) The pump drive shaft should be

connected to the motor drive assembly
with a flexible coupling, a double universal
joint shaft or an appropriate Zenith SJMC
coupling. Side loading on the pump shaft
is to be avoided at all costs.

6) If water is used for sealing, connect

either 1/8-27 or 1/4-18 NPT fittings to the
Rheoseal and turn on the water. Be sure
to avoid excessive cooling, or damage to
the pump may occur.

7) Turn on the pump heaters. A 250° F

temperature rise per hour is recommended
for cold starts. No attempt should be
made to start the pump until the entire
pump is at operating temperature. 

Cold

starts are the most common cause of
pump failure.  

On start-up, a small amount of molten

polymer should be introduced into the
pump by slowly rotating (less than 5 rpm)
the pump by hand to ensure that the
pump is free turning and well lubricated.
With sufficient inlet pressure, the pump
can then be started at a very slow speed,
with discharge pressure low enough to
maintain low loading. When operating 
satisfactorily, the pump and system may
now be gradually brought up to normal
process speeds and pressures.

Содержание PEP-II Series

Страница 1: ...Zenith Pumps Installation Care and Maintenance Zenith Polymer Extrusion Gear Pumps PEP II Series Gear Pumps ...

Страница 2: ...e critical issues in the diverse plastics industry The Zenith gear pump optimizes the extrusion process by allowing the screw to melt and homogenize the polymer As the pump generates the needed pressure it relieves the extruder of work therefore reducing heat from the shear lowering the torque required and eliminating surging All this optimizes the performance of the extruder and offers the follow...

Страница 3: ... and bottom of the center plate for the mounting of heat plates and for the mounting of the pump to its stand Thermocouple wells 1 8 27 NPT are located on the body of the pump A Zenith Rheoseal assembly secured to each cover plate front cover plate only on 3 0 cc rev and below prevents leakage around the shaft using both dynamic and static types of sealing mechanisms A Rheoseal consists of a helic...

Страница 4: ... 1 KEY EXTERNAL PUMP PUMP DIMENSIONS MAX APPROX CAPACITY A B C D E F G H I J TORQUE WEIGHT 0 16 3 000 3 000 2 860 1 400 2 400 1 960 0 750 1 4 1 500 0 125 80 9 0 3 3 000 3 000 2 860 1 400 2 400 1 960 0 750 1 4 1 500 0 125 80 9 0 6 3 000 3 000 2 860 1 400 2 400 1 960 0 750 1 4 1 500 0 250 195 9 1 2 3 000 3 000 3 650 1 400 2 400 1 960 0 750 5 16 2 500 0 750 410 9 1 8 3 000 3 000 3 650 1 400 2 400 1 9...

Страница 5: ...H I J TORQUE WEIGHT 5 3 250 3 250 3 250 1 125 2 875 2 125 0 500 1 4 1 875 0 750 1225 10 10 4 000 4 000 4 000 1 188 3 375 2 615 0 625 5 16 2 344 1 000 2085 18 20 4 750 5 000 5 000 1 188 3 750 3 300 0 750 3 8 2 813 1 250 3250 34 40 5 750 6 000 6 250 1 188 4 438 4 000 1 000 7 16 3 531 1 500 6750 61 100 8 000 8 250 8 250 1 750 5 438 5 458 1 250 5 8 4 688 2 188 12100 150 175 9 500 9 750 9 880 1 813 6 3...

Страница 6: ...ature thread lubricant such as DAG Dispersion 154 Felpro C 100 or equivalent 2 Place the top heat plate on the pump then place the insulation jacket on top of the heat plate Install and tighten the bolts taking care not to crack the insulation block 3 Repeat for the bottom plate noting that bottom heat plate mounting bolts are typically used to mount the pump to its mounting block 4 Place the supp...

Страница 7: ...ances As with any other Zenith pumps PEP II pumps may be returned to Zenith for complete rehabilitation as necessary This procedure may be desirable if only a few pumps are involved If a large number of pumps are to be maintained at the user s plant it may be worthwhile to have key maintenance personnel attend a mainte nance seminar at the Zenith factory to view the manufacturing gauging and assem...

Страница 8: ...ete assembly Again soaking the parts in lubricating penetrating oil or other non damaging solution will help ease the disassembly Do not force the parts out one side with a hammer or arbor press 7 Slide the gear shafts and bearings out of the center plate They will not come out separately as the gear teeth will not clear the bearings Take extreme care not to nick or ding the gear teeth or the edge...

Страница 9: ...the driven shaft taking care to select a bearing with the proper groove configuration Set the flats on the circum ference of the bearings against each other and gently slide the bearings and shafts into the center plate Slide them far enough through the center plate to allow the drive shaft to protrude out on the front side and allow the front bearings to be installed See D bearing orientation sch...

Страница 10: ...l gently press the lip seal into the Rheoseal housing Do not attempt to press on the lip seal with screwdriver or other pointed object as this will damage the seal Do not press the lip seal all the way into its cavity Instead allow it to protrude slightly so that it will be correctly seated by the seal cover Carefully remove the special Zenith tools 14 Slide the seal cover over the shaft until it ...

Страница 11: ...urrent and speed settings Check all drive couplings 3 Process conditions changed Check process conditions for proper melt temperature pres sures viscosities and materials 4 Entrained particle Disassemble and clean pump replace any damaged parts 5 Possible internal damages Disassemble and clean pump replace damaged parts Consult factory Excessive seal assembly leakage 1 Worn lip seal Replace lip se...

Страница 12: ...ty of operating conditions and applications for these products or systems the user through its own analysis and testing is solely responsible for making the final selection of the products and systems and assuring that all performance safety and warning requirements of the application are met The products described herein including without limitation product features specifications designs availab...

Отзывы: