Zenith Miniboil Скачать руководство пользователя страница 7

7

805757NZ v1.06 07.21 Miniboil Install Instructions

Flow Direction

Pressure 
Limiting 
Valve

Fig. 2  External Filter Connection 

Flush Tube

Flush Valve

Installation

Step B - Installing the filter

Miniboil is supplied with an external filter (see diagram below). It is 
important the filter be securely fixed adjacent to the under sink unit in 
such a manner as to allow for easy access to the filter, for service and 
regular replacement.
The ¼” LDPE tube supplied must be carefully measured and cut to 
allow for the connection of the filter, double check valve and JG 
fittings.

Step C - Installing the Command Centre 

Position the Command Centre as close as possible to the tap.
The connection tubes supplied with the tap assembly CANNOT be 
lengthened. 
Allow at least a 50 mm air-gap to the RHS for air circulation.
Allow a 70 mm clearance on the LHS of the appliance to ensure the 
power lead is free from external force.

IMPORTANT: Proper air circulation and adequate 
cupboard ventilation is necessary for efficient 
operation.   

Adjust cupboard door hinges and attach the supplied silicone 
door buffers to create a 4 mm air-gap between the doors and the 
cupboard. This is the minimum ventilation requirement for low 
usage installations. Failure to do this may cause the appliance to 
overheat and operate inefficiently.

Step D - Connecting the water supply

To prevent sediment from the in-wall plumbing entering the 
Command Centre at connection, flush water through the supply line 
thoroughly before connection.

!

Filter assembly sequence: (see Fig 2)

Fit the pressure limiting valve to the outlet side of the 
isolating valve (not supplied).
Mount the filter and flush valve assemblies in a convenient 
position using the angle bracket supplied.
Connect the filter assembly plumbing between the 
pressure limiting valve and the inlet of the Command 
Centre using the ¼” JG fittings supplied (see Fig 1). Take 
note of the flow direction, marked with an arrow on the top 
of the filter head.
Ensure the flush valve is accessible after installation as this 
will be required to flush water through the filter, when the 
filter is installed or changed. 

Fig 1. John Guest  (JG) 
fittings - Assembly and 
Removal

Содержание Miniboil

Страница 1: ...1 805757NZ v1 06 07 21 Miniboil Install Instructions Installation instructions user manual Zenith Miniboil AFFIX PRODUCT LABEL HERE 805757NZ Models Boiling Ambient Boiling Only ...

Страница 2: ...t of the appliance when full of water Before Commissioning 1 Check the unit has been secured correctly 2 Flush the supply line before connecting 3 Check all plumbing fittings have been tightened 4 Ensure the outlet and vent pipes are positioned to drain correctly 5 For command centres ensure there is adequate ventilation 6 Check all tubes from the Command Centre to the tap have a constant rise and...

Страница 3: ...allation requirements 5 Special tools required 6 Installation 6 Step A Installing the tap 6 Step B Installing the filter 7 Step C Installing the Command Centre 7 Step D Connecting the water supply 7 Step E Connecting the tap 8 Step F Testing and commissioning 8 Operation 9 Font installation 10 Cleaning 11 End of Life Disposal 11 ...

Страница 4: ...es steam and or boiling water may discharge through a vent outlet at the mouth of the tap If the tap is not installed using the Font pedestal ensure the tap body is located so the tap outlet safely drains into the sink bowl area Lifting Take care when lifting the Command Centre Some units may exceed safe lifting limits Do not lift without assistance The weights of the units are given in the table ...

Страница 5: ...n site Sufficient space in the cupboard to install the command centre in accordance with these Installation Instructions NOTE Allow clearance of 50 mm around all sides and 200mm above the command centre for air circulation A water supply connection with isolating valve inside the cupboard within reach of the 750 mm flexible connection and positioned so that the connection point and the stop cock w...

Страница 6: ...sture seal against the bench sink top A light smearing of silicon sealant on the underside of the spacer will ensure a watertight fit 4 Pass the hoses through the 35mm hole and carefully locate the Head Assembly and black spacer on the bench sink area 5 From the underside of the bench sink area re locate the S S washer and Spider Clamp by feeding each of the tubes and electrical cable evenly in be...

Страница 7: ...ecessary for efficient operation Adjust cupboard door hinges and attach the supplied silicone door buffers to create a 4 mm air gap between the doors and the cupboard This is the minimum ventilation requirement for low usage installations Failure to do this may cause the appliance to overheat and operate inefficiently Step D Connecting the water supply To prevent sediment from the in wall plumbing...

Страница 8: ...Centre It should be fitted together tightly until a click is felt Failure to fully insert the connector will prevent tap operation Once connected fix the cable to the wall ensuring it is off the floor and away from any possible water splashes Turn on water and check for leaks Step F Testing and commissioning The appliance is now running in normal operating mode The Red LED will flash until factory...

Страница 9: ...ashing there is a fault in the unit In that case switch off the unit for at least 20 seconds If the fault has not been corrected when the unit is switched on again contact customer service Change Filter light Boiling Ambient model ONLY Off Indicates the water filter is operating within its normal specified lifespan Flashing slowly Indicates the water filter is due for replacement after 12 months o...

Страница 10: ...d period of time proceed as follows 1 Turn off the water supply 2 Use the tap to dispense ambient and hot water until no more water flows to empty the system 3 Disconnect the appliance from the power supply After prolonged non use 1 Reconnect the water supply Pay attention to any leaks 2 Reconnect the appliance to the power supply 3 After non use of several days Drain at least four litres of ambie...

Страница 11: ...ned on Check for loom connection Slow water recovery after use Unit is in Sleep Mode Possible internal fault Touch Hot lever and wait for Red LED to stop flashing Wait for Red LED to stop flashing Contact local Zenith Service Provider All the lights are flashing Power interruption Water interruption System Fault Turn OFF power for 20 seconds and then turn back on Check for blockages Contact local ...

Страница 12: ...enith and HydroTap are registered trade marks of Zenith Heaters Ltd Zenith products described in this publication are manufactured under one or more patents and further patent applications are pending As Zenith policy is one of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of t...

Отзывы: