8
Quick Start Installation Guide
806836NZ v1.02 02.22 G5 B BA Quick Start Guide
A pressure limiting valve must be fitted for mains water pressures
above the maximum limits stated above in accordance with local
plumbing regulations.
Note: All models (excluding UK) have an internal pressure limiting device
to reduce the maximum mains regulated pressure (700kPa in NZ/Australia),
protecting the system against pressure surges above 500kPa.
!
Water supply connection
1/2” BSP (G1/2)
Booster specification
Specification
Rating
Nominal power
2.2kW
Nominal current
10A
Flow rate
1.2 L/m
Water supply pressure requirements
Component
Power rating
kW
Dimensions
W x D x H (mm)
Weight
(kg)
B100, BA100
1.8 + 2.2*
280 x 313 x 333
13
B60, BA60
1.8
280 x 313 x 335
13
B, BA Home
1.35
280 x 313 x 335
13
* power rating of the booster
Component
Min - Max pressure, kPA (bar)
NZ/Australia
HydroTap
170 (1.7) - 700 (7.0)
Vented Mixer Tap
300 (3.0) - 700 (7.0)
Booster
200 (2.0) - 700 (7.0)
Limescale filter
200 (2.0) - 700 (7.0)
Electricity supply requirements
220-240V 50Hz AC (for power requirement see table above).
Without booster
With booster
1x 220 - 240V AC 10A socket
2x 220 - 240V AC 10A sockets
SECTION 4: Technical data