6
Quick Start Installation Guide
806836NZ v1.02 02.22 G5 B BA Quick Start Guide
•
The Zenith HydroTap must be earthed. The resistance of the earth
connection from each exposed metal part must be less than 1Ω . Use the
power cable supplied. It is the responsibility of the installer to ensure
the power point is earthed.
• All installation and service work must be completed by trained and
suitably qualified tradespeople. Faulty operation due to unqualified
persons working on this product, may void warranty coverage.
• As the installer, it is your responsibility to supply and install all valves as
required by local regulations and relevant standards.
• The HydroTap is rated for 220-240V 50Hz AC operation.
• Do not remove the cover of the appliance under any circumstances
without first isolating the appliance from the power supply.
• Connect only to a potable (wholesome, cat1) mains water supply.
• Never locate the system near, or clean with water jets.
• Do not expose the Zenith HydroTap to the elements of nature.
SECTION 3: WARNINGS & REGULATORY INFORMATION
• The booster complies with protection class IP 20.
• For UK, a pressure limiting valve must be fitted for mains water
pressures above the maximum limits stated.
• Use of tools can be hazardous. Assess the risks before you start.
• A clearance envelope around all Command Centres must be provided
to allow adequate ventilation for the safe and effective use of the
HydroTap system.
!
!
• For continued safety of this appliance it must be installed,
operated and maintained in accordance with the
manufacturer’s instructions.
• This appliance may deliver water at high temperature. Refer
to the Plumbing Code of Australia (PCA), local requirements
and installation instructions to determine if additional
delivery temperature control is required.