802253NZ - HT BC Residential Instructions 10.18 v3.00 

Page 27 of 28

Notes

Содержание HydroTap G4

Страница 1: ...802253NZ HT BC Residential Instructions 10 18 v3 00 Page 1 of 28 Affix Model Number Label Here 802253NZ Zenith HydroTap G4 Installation and Operating Instructions BC Residential...

Страница 2: ...Classic Tap Elite Tap Arc Cube Mixer Classic All In One Celsius All In One These taps are directly compatible with the HydroTap G4 Command Centre The All In One Tap is a stand alone tap that may be us...

Страница 3: ...or All Models 11 2 2 Cupboard Air Ciculation 12 STEP 3 Install the Booster Heater if required Section 3 Booster Heater Installation 3 1 Product Description 14 3 2 Installation Procedure 15 3 3 To Remo...

Страница 4: ...ble for the appliance F Check the under counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been in...

Страница 5: ...designed to be used for sanitary fixtures The Boiling water units are fitted with a tap mounted child safety lock In addition there are various energy saving options accessible via the main menu Each...

Страница 6: ...be carried out by a suitably qualified tradesperson The power cable and power outlet must be in a safe visible position for connection Venting Sometimes steam and or condensed droplets may discharge...

Страница 7: ...n and service work must be completed by trained and suitably qualified Tradespeople Faulty operation due to unqualified persons working on this product or any other Zenith product may void warranty co...

Страница 8: ...ription 1 x Tap option with hoses Classic Tap shown 1 x HydroTap Undersink Unit with air and water filters 1 x Mains water connection hose 1 x Connector Strainer Sub assy Vent Kit 1 x Inlet vent 1 x O...

Страница 9: ...lation Before installing ensure that the following have been provided at the Installation site Review all the technical specifications Ensure the underbench can support the product weight when full of...

Страница 10: ...working pressure of 150kPa 200kPa when a booster and or filter softener is fitted and a maximum working pressure of 700kPa connected via an isolation valve The appliance must be placed with its base...

Страница 11: ...NT Allow a clearance envelope of 50mm either side and 300mm above the undersink unit Ventilation options will be dependent on usage High usage applications will require additional ventilation It is re...

Страница 12: ...pplications where the cupboard space temperature is near 35 C or higher the inlet vent Item B below and silicon buffers need to be fitted If the airflow is still insufficient to maintain normal operat...

Страница 13: ...t 1 Mark out and cut the air inlet and door outlet holes as shown 2 Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cupboard space 3 Fit the inlet vent as sho...

Страница 14: ...water delivery 280mm Booster Specifications Rating Unit Nominal Power Rating 2 2 kW Nominal Current 10 A Electric Supply 50Hz AC 230 V Elect flex and plug 1 meter length with 90 Australian plug 10 A F...

Страница 15: ...ctions on top of the Booster The hot water outlet hose must be thermally insulated with the insulation provided Tilt Forward Lift UP Release NOTE Remove the backing plate for wall mounting 3 3 To remo...

Страница 16: ...hose connections 1 Remove the bypass loop from the top of the command centre 2 The cold water inlet blue and hot water outlet red are marked on the rating plate Connect the braided hoses from the Bypa...

Страница 17: ...ps Only remove the mixer caps if a mixer tap is to be fitted Install the mains water braided hoses to the undersink unit before locating the unit in place NOTE Do not overtighten John Guest fittings I...

Страница 18: ...BOILING OUT BYPASS IN VENT BYPASS OUT CHILLED OUT Note The tube lengths are matched to the pump performance and therefore CANNOT be lengthened Note the hoses need to have a constant downward gradient...

Страница 19: ...BYPASS IN VENT BYPASS OUT CHILLED OUT Not required for AIO mains pressure HydroTap Note The tube lengths are matched to the pump performance and therefore CANNOT be lengthened Note the hoses need to...

Страница 20: ...Vented Tee piece and Flow Restrictor supplied to Mixer RED CLEAR BLUE BRAIDED USB MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT CHILLED OUT Booster HT Mixer connections BRAIDED BRA...

Страница 21: ...In One Vented Note The tube lengths are matched to the pump performance and therefore CANNOT be lengthened Note the hoses need to have a constant downward gradient to the Hydrotap to allow all water...

Страница 22: ...res of water to flush through the filter 4 Once the filter flush is finished Turn the stop cock OFF then press Stop to end filter flush mode Have a 10L bucket or similar container not supplied at the...

Страница 23: ...ng to make the correct selection for the Booster will affect product performance NOTE Depending on your location you may need to re set the internal clock See section G of the user guide to check and...

Страница 24: ...ormed at the time of the installation All direct natural sun light must be shaded from the HydroTap during the calibration This can be achieved by closing any nearby curtains blinds or by shielding th...

Страница 25: ...Service Condenser sensor Open Internal fault Check ventilation Call Zenith service Heater fuse driver fault Internal fault Call Zenith Service Heater driver fault No hot water Call Zenith Service Com...

Страница 26: ...T BC Residential Instructions 10 18 v3 00 End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for co...

Страница 27: ...802253NZ HT BC Residential Instructions 10 18 v3 00 Page 27 of 28 Notes...

Страница 28: ...800 558 055 As Zenith policy is one of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true represent...