P A G E 4 1
206-3753
Item
Description
Range
Fact. Set
Recommended Setting
00
FACT MENU
0 - 1
0
Leave default set 0
01
PRESET PX
0 - 1
1
02
PRESET AX
0 - 1
1
03
POWER MANAGE
0 - 7
0
04
VERT POS
0 - 30
15
05
HORZ POS
0 - 45
31
06
BAND/AFC
0 - 7
0
07
MIN VOLUME
0 - 63
0
08
MAX VOLUME
0 - 63
63
09
AC ON
0 - 1
0
10
KEY DEFEAT
0 - 1
0
11
STRT CHANNEL
0 - 255
255
12
STRT VOLUME
0 - 63, 255
255
13
HOSPITAL MODE
0 - 2
0
Leave default set 0
14
CHAN LOCK
0 - 1
0
15
GHOST CH.
0 - 1
0
16
SCAN MODE
0 - 3
0
Leave default set 0
17
TEXT MODE
0 - 1
1
18
SLEEP TIMER
0 - 1
1
19
CH. OVER RIDE
0 - 1
1
20
OLD OCV
0 - 1
0
21
CAPTION LOCK
0 - 1
0
22
FUNCTION PRE
0 - 1
0
23
FEATURE LEVEL
0 - 1
1 Zen 1/0 P Lbl
Leave default set 1 (1 Zen 1)
Installer Menus
Use the Installer Menus to change the operational setup
221-01535 1.05 01
03 POWER MANAGE 0
XX/XX/XX TE = 10110000
Accessing the Installer’s Menu
Installer’s menus can be accessed by using the installer’s remote control. Just press
and hold MENU (about 8 seconds) until the display changes, then press 9, 8, 7, 6,
then ENTER. To exit the Installer’s Menu, press ENTER again.
Any changes you make
will be stored in nonvolatile memory.
The Installer’s Menu opens with item 03, POWER MANAGE. Press the Up arrow key to
sequence through the various items. Or, access an item directly by entering the line
number, then pressing MENU. For example, to access the Start Channel option which
is on line 11, press 11, then MENU. To change a setting, use the Left/Right arrow
(Adjust) keys.
Using the Installer’s Menu
Items 00-23 are immediately accessible only upon entering the Installer’s Menu.
Their numbers, descriptions, ranges, factory default settings, and a place for listing
any changes made on-site are given below. A second section of the Installer’s Menu
that is intended for qualified service technicians only is not shown (items 24-93).
Normally these items do not require adjustment.
Items in the Installer’s Menu:
Installer should leave item
00 FACT MENU set to 0
(default).
Items 24-93 are
service-type adjustments and
only qualified technicians having special-
ized test equipment should access them.