FlushMaster Solo Installation & Maintenance Instructions - 87278 - January 2011
Page 3 of 12
Key Features
One of the world’s most effective, ceiling recessed, urinal flushing systems.
This unit is supplied with a power pack for connection to 220-240 volt AC power.
Smart Demand electronic programming allows for a variable flush cycle to meet
your needs precisely.
Narrow sensitivity beam protects against unwanted flushing operations.
Read These Warnings First
Read all instructions before attempting to install this system.
Never attempt to install this system without reading all instructions.
This unit is designed for indoor use only and should never be installed outdoors or
exposed to the elements of nature. This unit must not be positioned in an area that
may be cleaned by a water jet. This unit must not be cleaned with a water jet.
All plumbing connections must be made in accordance with AS/NZS3500 and
installation with AS/NZS3500.2.
Supply pressure 350kPa - 700kPa ( see recommendations on P7 )
Installation Procedure
1.
Set up water discharge with isolating valve, Latching Valve and Airbreak
2. Install
sensor
3.
Connect latching valve cable
4. Set
flush
timing
Check Your Package
Zenith FlushMaster
Solo package
includes.
Zenith FlushMaster Solo WS005 Product
Code 42214:
Ceiling recessed Solo sensor complete with
latching valve, power pack and plumbing
Isolation:
An Isolation valve (not supplied) must be fitted, in an accessible position, upstream
of this installation.