Tap installation

In addition to common tools, the following will be required:

•   25mm (ChillTap Standard/Heavy Duty) OR 35mm (ChillTap 

Extra) diameter sheet metal hole punch for sink tops (not 
supplied)

•  25mm (ChillTap Standard/Heavy Duty) OR 35mm (ChillTap 

Extra) diameter hole saw for timber bench tops (not 
supplied)

Position the Tap

Warning: Do not reuse old hose-sets. The unit shall be 
installed with the new hose-sets supplied. Hoses are 
maximum 1000 mm in length. 

Position and install the tap at the back of the sink or on the Font, 
where there is a minimum 52 mm wide flat area within the draining 
area of the sink. Make sure the selected position allows the tap 
spout to overhang the sink bowl.
Ensure the distance between the tap and the command centre 
does not exceed the length of the supplied tubing. 

ChillTap Standard/Heavy Duty (Fig.1)

Use a 25mm sheet metal punch or hole saw to create a neat hole 
without burrs.
Remove the large nut from the base of the tap, leaving the rubber 
sealing ring (O-ring) in place.
Fit the tap and O-ring to the sink top, oriented so the operating 
lever is easily accessible.
From under the sink, slide the nut over the tubes. Tighten the nut 
to secure the tap firmly into place.

ChillTap Extra (Fig.2)

Use a 35mm sheet metal punch or hole saw to create a neat hole 
without burrs.
Remove the large nut with the stainless steel and rubber washers 
from the base of the tap, leaving the rubber sealing ring (O-ring) in 
place.
Fit the tap and O-ring to the sink top, oriented so the operating 
levers are easily accessible.
From under the sink, slide first the rubber washer, and then the 
brass washer, followed by the nut, over the tubes. Tighten the nut 
to secure the tap firmly into place.

O-RING

LOWER 
RUBBER 
WASHER

WASHER

NUT

Blue tube to 
Chilled Outlet

Red tube to 
Vent Outlet

White tube 
to Ambient 
Outlet

O-RING

White tube to 
Chilled Outlet

Blue and Red 
tubes to Tee piece 
which connects 
to Vent Outlet.

Fig.2 ChillTap Extra

Fig.1 ChillTap Standard / Heavy Duty

NUT

Installation instructions

Содержание ChillTap 140 glass

Страница 1: ...1 806143NZv1 0607 19CWChillTapUCCT Installation instructions user manual Zenith ChillTap Filtered chilled water on tap AFFIXPRODUCTLABELHERE ...

Страница 2: ...hnical specification 04 Before installation 04 Installation instructions 05 Tap installation 05 Ventilation 06 Command centre installation 08 Commissioning 09 Operation Maintenance 10 Operation 10 Water filter 10 Air inlet screen 10 Troubleshooting 11 Cleaning 11 End of life disposal 11 ...

Страница 3: ...s designed for indoor use and must not be installed outdoors or exposed to the elements of nature 9 This unit must not be positioned in an area that may be cleaned by a water jet 10 This unit must not be cleaned by a water jet 11 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they ...

Страница 4: ...tra filtration will be required Check the appliance rating plate and ensure correct power is available for the appliance Check the underbench cupboard supporting the appliance is adequate for the total weight and size of the appliance Power supply 220 240V AC 50Hz for connection via a 10 amp electrical power outlet Operating temperatures 5ºC 35ºC External water pressure 150kPa 700kPa 1 5 bar 7 bar...

Страница 5: ...e a neat hole without burrs Remove the large nut from the base of the tap leaving the rubber sealing ring O ring in place Fit the tap and O ring to the sink top oriented so the operating lever is easily accessible From under the sink slide the nut over the tubes Tighten the nut to secure the tap firmly into place ChillTap Extra Fig 2 Use a 35mm sheet metal punch or hole saw to create a neat hole w...

Страница 6: ...ChillTap must be installed in the cupboard The vent kit ensures heat dissipation through forced convection Air is drawn in through the front vent and expelled from the command centre Residential models are supplied with a 2 piece vent kit See Fig 4 cut out B The second grille may be installed in the cupboard door side wall if required Commercial models are supplied with a 4 piece vent kit See Fig ...

Страница 7: ...igsaw and Keyhole or Wall Board saw 60 00 B C 12 00 45 00 284 Additional ventilation The following instructions are critical if the vent kit as supplied cannot be fitted If the vent kit cannot be used or for high use applications where the cupboard space temperature is 35 C or higher an optional Vent Tray Kit or Exhaust Fan kit may be fitted Contact your local service centre for more information V...

Страница 8: ...pplied in the water supply line before the connection to the product Connect the braided hose to the isolation valve installed in the mains water supply line For best results the recommended minimum static pressure is 250 kPa 2 5 bar Connect the braided hose from the isolation valve to the top of the command centre marked MAINS IN see Fig 5 On Off Switch If caps are removed to allow lifting handle...

Страница 9: ...rd and ChillTap Heavy Duty and Fig 7 for ChillTap Extra Push each hose into the quick release connector as far as it will go approx 15 mm to ensure a tight connection ChillTap Extra BLUE WHITE RED ChillTap Extra WHITE Ambient BLUE Chilled RED Vent Fig 7 ChillTap Standard Heavy Duty WHITE Chilled BLUE Tee piece side RED Tee piece top BLUE WHITE RED Tee piece ChillTap Standard ChillTap Heavy Duty Fi...

Страница 10: ...d below the filter head 4 Fit a new filter by turning filter anti clockwise and gently pushing up The filter will click or lock into place 5 Turn on the water supply to the unit 6 Turn on the chilled water tap and dispense at least 7 5 litres 7 Turn off the chilled water tap 8 Turn on the power supply to the unit 1 ROTATE 2 PULL DOWN 1 INSERT 2 ROTATE REMOVE FILTER INSERT FILTER Warning Not changi...

Страница 11: ...ith Service Provider Internal water leak Contact local Zenith Service Provider Water not chilled No power Restore power to the unit Thermostat faulty or out of calibration Contact local Zenith Service Provider Insufficient cooling air flow through the refrigeration system Check and clean air inlet screen Refrigeration failure Contact local Zenith Service Provider Rated chilled water capacity has b...

Страница 12: ...8 8612 Free Call 0800 558 055 Products described in this publication are manufactured under one or more patents and further patent applications are pending As Zenith s policy is one of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true representations of the finished goods 2019 Zenith Heaters Ltd ...

Отзывы: