802006NZ - HT-BCS;BCSH A-AV User Manual - May 2016- v3.00  

Page 5 of 32

3.  

    

Tap functions

MixerTap:

Lifting the handle up will 
decrease the flow rate and 
lowering the handle will 
increase the flow rate. Raise 
the handle all the way up to 
turn the tap off.
When the handle is moved 
towards the BLUE mark, the 
temperature is decreased 
and when moved towards the 
RED mark, the temperature 
is increased. The final 
temperature will depend 
on the temperature of the 
incoming cold water.

On power up, wait 30secs. 
for the unit to calibrate itself. 
Tapping the select button will 
allow the choice of Boiling 
(RED) with safety, Chilled 
(BLUE) or Sparkling (WHITE) 
water mode. The Arc/Cube 
control may be rotated in a 
forward or reverse direction 
to dispense Boiling or Chilled 
water.
The rotary control is spring 
loaded in the anticlockwise 
direction and when released, 
will return to the OFF position. 
When rotated clockwise the 
tap operates in a “Pot fill” 
mode. Water will flow from  
between 5 and 15 seconds 
(This is user adjustable). To 
reset, return the handle to the 
“Off” position and repeat the 
step. The lever has to be manually returned to the “Off” position.
After activating the Boiling mode, all the lights will flash for 2 seconds, during 
which time you may dispense water. When the rotary control is returned to the 
Off position the light will continue to flash for an additional 3 seconds, allowing 
you to dispense more water. 
When unattended, the control light will automatically default to the Chilled 
(BLUE) mode after 30 seconds.

Rotary control

Select Button

Safety Lock

HydroTap Arc/Cube: 

Содержание 802006NZ

Страница 1: ...G4 User Manual Tap Operation Pages 3 11 LCD Screen Menu Pages 12 26 Maintenance Pages 26 29 Home Menu Icons Page 30 Contact details Page 32 Date of Installation Affix Model Number Label Here 802006NZ...

Страница 2: ...Page 2 of 32 802006NZ HT BCS BCSH A AV User Manual May 2016 v3 00 Notes...

Страница 3: ...assic Elite AIO From the tap After selecting to allow the safety setting from the menu screen Place a finger on the safety lock then depress the Classic Blue Chilled lever or touch the Elite Blue Chil...

Страница 4: ...Tap The two levers are used for dispensing Boiling Chilled and Sparkling water The safety button operating in the same way as on the HydroTap The Mixer tap lever is operated as a classic Flick Mixer T...

Страница 5: ...ed in a forward or reverse direction to dispense Boiling or Chilled water The rotary control is spring loaded in the anticlockwise direction and when released will return to the OFF position When rota...

Страница 6: ...he handle to the Off position and repeat the step The lever has to be manually returned to the Off position NOTE Chilled water will not be dispensed if the safety button is accidentally covered Elite...

Страница 7: ...dicator light turns RED Then tap the safety button twice until the RED light flashes This will flash for aprox 2 seconds Boiling water may be dispensed by rotating the control while the RED light is f...

Страница 8: ...n and repeat the step The levers have to be manually returned to the Off position To dispense Sparkling water HydroTap Arc Cube Tap the select button until the indicator light turns WHITE Rotating the...

Страница 9: ...t the chilled water is not within the set temperature range While flashing water may be dispensed but not at the set temperature When the chilled water is at the set temperature the light will stop fl...

Страница 10: ...is due for replacement and the LCD will show Filter Change Refer to Replacing the filter in section C of this document Filter Lights HydroTap Arc Cube Flashing filter lights All three tap lights Safet...

Страница 11: ...tion 7 To check the calibration dispense Boiling water in normal light conditions with the safety enabled Light intensity varies from site to site therefore it is recommended that a re calibration be...

Страница 12: ...ct is in normal operation mode Safety ON Safety lock is activated Refer to section G safety System Fault Product has one or more system faults Refer to section B Sleep Mode System is in sleep mode Boi...

Страница 13: ...ush Filter Reset Boiling Calibration Booster Lux sensor calibration Reset options Calibration options C Service Password protected D Security Enable Password Set Password Change Password E Communicati...

Страница 14: ...Info to view the product information 2 Press button for the previous menu or press Home button to return to the home screen 1 Press System Faults to check the fault information 2 Press button for the...

Страница 15: ...utton to display the main menu Sub menu 1 Filter Flush 2 Filter Reset 3 Boiling Calibration 4 Booster 5 CO2 Purge 6 Lux Sensor Calibration 7 Advanced options 8 Reset LCD Screen operation Section C 1 P...

Страница 16: ...On start up the hydroTap starts a self calibrating program The controls take the system through the calibration process Once complete the system reverts back to normal operation If you would like to...

Страница 17: ...t screen press the START button to commence the purging process 5 Wait for the water to stop flowing through the unit 6 Wait a further 10 seconds after the water has stopped flowing During this time y...

Страница 18: ...recovery period Disabling may overcome the flickering lights however the unit may experience increased steaming Fan speed adjustment If the undersink unit is operating near 35 C then the fan speed mus...

Страница 19: ...s When activated the password will be necessary to access the Settings and Comms areas To set a password 1 Press the MENU button for main menu 2 Press the Security button 3 Press Enable Password 4 Ent...

Страница 20: ...e set up instructions supplied with the WiFi unit LCD Screen operation Section F G Settings 3 LCD Screen operation Section G g Instructions 1 Press the MENU button for main menu 2 Press the Settings b...

Страница 21: ...designed to operate within 1 C to 2 C of set point for boiling water and between 3 C to 5 C for chilled drinking water All boiling water units are self calibrating to 98 C which is the recommended set...

Страница 22: ...ote The filter life may be set as a function of Litres used or in months from the filter change When the first of these functions is reached i e Litres or months expired the filter warning light will...

Страница 23: ...her 68 C or room temp as shown in the table below and the Chilled water will be ON or OFF When the period of inactivity passes the home screen status window will show Sleep Mode Lux Light Sensor Calib...

Страница 24: ...e energy mode setting after 30 minutes of non use Note Any attempt during OFF mode to dispense water will bring the unit out of sleep mode The unit will return to sleep mode after 2 hours of non use P...

Страница 25: ...on if needed When activated the HOT Isolation mode will override the settings to ensure Boiling water is not dispensed To Activate the Hot Isolation Press button to Enable Disable Hot isolation To ope...

Страница 26: ...dispensing times to between 5 and 15 seconds in increments of 1 second To edit the dispensing times 1 Press the MENU button for main menu 2 Press the Setting button 3 Press the Dispense Time button 4...

Страница 27: ...d push the new cartridge into the filter head Turn the cartridge a quarter turn to the right until the cartridge comes to complete stop and is locked into position with the front label facing forward...

Страница 28: ...t The screen may be removed for cleaning by sliding it forward This needs to be inspected at least quarterly cleaned and replaced if damaged Note For best performance the unit should only be operated...

Страница 29: ...n an upright position use the velcro securing strap 5 Turn the regulator ON Clockwise and adjust to 2 7 3 0 bar Green zone on dial 6 Check all joints for gas leaks using a sponge and soapy water 7 Pre...

Страница 30: ...ayed no power is being supplied to the heating element See page 24 Filter use This icon displays the filter usage remaining from 100 New filter to 0 end of life When it reaches 0 the filter warning li...

Страница 31: ...CSH A AV User Manual May 2016 v3 00 Page 31 of 32 Notes This user manual has been written according to firmware version B02 4 Please check the following website for the latest user manual https www ze...

Страница 32: ...A2006 08043 Other patents are in force and patent applications are pending Head Office Zenith Heaters Limited IRD No 95 640 729 Unit 2 15 Moselle Avenue Henderson Auckland 0610 New Zealand Website www...

Отзывы: