16
17
6
Reattach the
TKIS
Kit
in the junction box, and verify that microphone and
speaker wires are correctly connected.
7
1. Run an Ethernet cable through the cable gland on the back plate, and
terminate the cable to a RJ45 connector.
2. Insert the Ethernet cable into the
TKIS
Kit
Ethernet port.
The speaker must be installed using a shielded Ethernet
cable with grounding at the switch end.
Cable Gland:
M20, clamping range of 5-12 mm.
8
1. Attach and fasten the lid.
2. Make sure to tighten the cable gland sufficiently to attain IP-66 rating
for watertightness, but be aware of plastic material limitations.
•
In order to ensure the required minimum degree of protection, the
cable glands must be tightened securely.
•
When tightening the cap nut of a cable gland, a suitable tool shall be
used to prevent the gland from twisting.
Speaker
+
Red
-
Yellow
Microphone
+
White
-
Black
Microphone
Wires
Speaker
Wires
Microphone
Gland
TKIS Kit
To guarantee the IP-66
rating, use a cable with
Ø 5-6 mm.