66
ZVC235-001_v03
3
Attach the other end of the hose (the handle) to the
suction tube. In order to do this, press the lock
A
in the
telescopic suction tube and put the tube in the handle, so the
lock
A
is fastened in hole
B
.
4
Select the needed length of the telescopic suction pipe
by sliding the slider according to the arrow, and pulling the
pipe out/in.
5
Install a nozzle or a brush on the other end of the suction
pipe.
6
Use combination carpet & floor brush for vacuuming both
hard surfaces and carpets. To clean hard surfaces – wooden
floors, plastic floors, ceramic tiles etc. pull out the brush by
pressing the switch on the combination brush according to
the figure
. Retract the brush when vacuuming carpets
(set the switch in “
”).
7
Grab the plug of the cord
(3)
, and pull it out of the
vacuum cleaner.
When pulling out the cord pay attention to
the yellow band which marks the end of the
cord. Any attempts to unwind the cord further
(especially forcefully pulling on it) may lead to
damaging it.
8
Put the plug of the cord in an electric socket.
Before turning the vacuum cleaner on, make sure the
CYKLON dust container is installed in the chamber of the
vacuum cleaner, and also the basic filter and the outlet filter
are installed in the vacuum cleaner.
9
Press the on/off button to start the vacuum cleaner.
10
The vacuum cleaner is equipped with an electronic
controller of suction power, which enables smooth regulation
of suction power of the vacuum cleaner. Turn the dial up or
down to respectively increase or decrease suction power.
11
The vacuum cleaner is also equipped with a mechanic
suction power controller, which is situated on the hose
handle. You may use it to slightly regulate the suction power
without the need to use the dial.
Installing/deinstalling the CYKLON dust
container
The vacuum cleaner is equipped with a removable CYKLON
dust container (which is a removable part of the vacuum
cleaner) responsible for collecting dirt. After the CYKLON
dust container is full, it has to be emptied.
The vacuum cleaner is equipped with a safety
valve situated in the chamber of the vacuum
cleaner. It opens up automatically when the
suction hose or any elements attached to it are
completely clogged up, and when the CYKLON
dust container is overfilled. After the valve is
open, you will hear a characteristic fluttering in
the vacuum cleaner.
1
Press the on/off button
(6)
to stop the vacuum cleaner.
Remove the plug of the cord from the socket.
C
2
Turn the end of the suction hose counter-clockwise, and
remove the end of the hose from the inlet of the vacuum
cleaner.
3
Release the fastening of the upper cover
(5)
, and open it.
4
Remove the CYKLON dust container from the vacuum
cleaner. In order to do this hold the body of the vacuum
cleaner by one hand, grab the special handgrip situated on
the cover of the dust container by the other, and by holding
it like that gently remove the CYKLON dust container out of
the vacuum cleaner.
5
Pull the fastenings on the cover of the CYKLON dust
container aside, and remove the cover from the container.
6
Move the CYKLON dust container over a dustbin, and
empty its contents.
After doing this, check the EPA E12 basic filter,
and clean or replace it, if necessary.
7
Place the cover of the CYKLON dust container on the
container in such a way that the fastening situated in the
front part of the cover is inserted into the projection of the
container. Press the back part of the cover in such a way that
the fastenings are shut tight on the body of the container.
The CYKLON dust container has to be shut
tight. Otherwise, the suction power of the
vacuum cleaner is going to drop.
8
Place the emptied CYKLON dust container into the
chamber of the vacuum cleaner. Close the upper cover of the
vacuum cleaner by pressing it, until you hear a characteristic
“click.”
It is necessary to empty the CYKLON dust container, if you
notice that:
a) the vacuum cleaner works less efficiently,
b) the CYKLON dust container is full.
Deinstalling the filters
The vacuum cleaner is equipped with the CYKLON dust
container based on cyclone filtration, making it possible to
use the vacuum cleaner without a dust bag. A cyclone filter
uses air stream swirling to separate solid dirt. Separation
of dirt is done in an O-shaped part of the container, where
the swirling air casts away dirt on the wall of the container,
and then through the hole into the adjacent chamber of the
container. This pre-filtered air is directed into the washable
EPA E12 conical filter stopping the tiniest fractions of dust.
A special filtration material used in the washable EPA E12
filter makes it possible to rinse the filter with running water,
if it is dirty, and reuse it later.
At the outlet of the vacuum cleaner there is a microfilter
installed.
In case the EPA E12 basic filter (14) or the
outlet microfilter (13) are dirty, they can be
replaced with new ones, cleaned or rinsed with
running water.
Содержание ZVC235SF
Страница 25: ...31 ZVC235 001_v03 Zelmer Zelmer 8 230 16 A RU...
Страница 30: ...36 ZVC235 001_v03 K PE...
Страница 31: ...37 ZVC235 001_v03 Zelmer Zelmer 8 230 V 16 A BG...
Страница 35: ...41 ZVC235 001_v03 3 8 4 c 5 A 6 7 8 EPA E12 14 6 EPA E12 1 13 2 13 3 4 4 BNB Brush Natural Bristle 22 1 6 2 E F...
Страница 36: ...42 ZVC235 001_v03...
Страница 37: ...43 ZVC235 001_v03 Zelmer Zelmer 8 230 16 A UA...
Страница 41: ...47 ZVC235 001_v03 4 5 A 6 7 8 a EPA E12 14 1 13 2 13 3 4 4 BNB Brush Natural Bristle 22 1 6 2 3 8 E F...
Страница 42: ...48 ZVC235 001_v03 PE 26663 19848 5 40 1 15150...
Страница 63: ...Notes...
Страница 64: ...Notes...