67
ZVC315-002_v01
2
Press the button located on “CYCLONE” dust container
and open the bottom of the container. If “CYCLONE dust
container is full, empty it according to the point
(C)
.
3
Turn the cone left, so the two tips located on the flange of
the cone were put out from the slots of the container. Put out
the cone.
4
If the “CYCLONE” dust container cone
(17)
is dirty, you
can rinse it with running water. Do not forget to dry above
mentioned cone before re-installation.
5
Insert the rinsed cone of “CYCLONE” dust container
into the container slot so the tip located on the flange of the
cone was in the slot of container’s body. Turn right the cone
so that the two tips located on the flange of the cone were
blocked in the slots of the container.
6
Snap the bottom of “CYCLONE” dust container. Please
pay attention to the proper positioning of seal found on the
bottom of the container.
7
Insert “CYCLONE” dust container to vacuum cleaner
chamber. The characteristic “click” indicates that the
container has been correctly mounted.
End of operation, cleaning and
maintenance
1
Switch off vacuum cleaner pressing On/Off switch
(4)
.
2
Put the connection cable plug out the wall outlet.
3
Wind the cable by pressing retractor button
(6)
.
Performing this action, hold the power cable to avoid any
tangles and shocking the vacuum cleaner body with the plug.
4
Disconnect telescopic suction tube and a sucker or
a brush sweeper.
5
Disconnect telescopic suction tube and a hose.
6
Press the two side buttons located at the hose end, then
remove the hose end from vacuum cleaner inlet hole.
7
Vacuum cleaner can be stored either in vertical or
horizontal position. The hose may remain attached to the
vacuum cleaner, but please note that the hose should not be
strongly bent during storage.
Storing in horizontal position:
–
Insert a fixing hook of sucker-brush sweeper to a hook
for fixing the sucker-brush sweeper located on the back
of the vacuum cleaner over the outlet filter cover.
Vertical storage:
–
place the nozzle brush on the telescopic pipe,
–
then insert the hook of the telescopic pipe into the
fastening situated on the bottom of the vacuum cleaner,
near the front wheel.
8
If necessary, clean the casing and the chamber of the
vacuum cleaner with a damp cloth (it may be damped in
dishwashing liquid), dry it off, and wipe it dry.
Do not use any scrubbing agents or solvents.
G
4
Insert “CYCLONE” dust container with mounted HEPA
H13 inlet filter
(14)
to vacuum cleaner chamber. The
characteristic “click” indicates that container has been
correctly mounted.
It is recommended to replace HEPA H13 inlet
filter (14) with a new one every 6 months of use.
Do not vacuum without HEPA H13 inlet filter
(14) installed in “CYCLONE” dust container.
Lack of HEPA H13 inlet filter (14) shall prevent
insertion of “CYCLONE” dust container to the
vacuum cleaner.
“MICROFILTER” OUTLET FILTER AND OUTLET
FOAM FILTER
1
In order to replace “Microfilter” outlet filter
(12)
press the
hook located in the filter cover and pull out the filter cover
from vacuum cleaner.
2
Pull out the “Microfilter” outlet filter
(12)
.
If the “Microfilter” outlet filter
(12)
is dirty, you can replace
it with a new filter, you can clean it or rinse with running
water. Do not forget to dry above mentioned filter before
re-installation.
For safety reasons it is unacceptable to install
the moist or defective “Microfilter” outlet
filter (12).
3
Carefully insert a new / rinsed filter to previously
occupied space.
4
Pull out the foam outlet filter from filter cover
(1)
.
If the outlet foam filter
(13)
is dirty, you can replace it with
a new filter, you can clean it or rinse with running water. Do
not forget to dry above mentioned filter before re-installation.
For safety reasons it is unacceptable to install
the moist or damaged outlet foam filter (13).
5
Carefully insert a new / rinsed filter to previously
occupied space.
6
Put the filter cover so that two tips located at the right
side of the cover should hit the holes in the body of the
vacuum cleaner, press the filter cover so the hook snapped
in the body. Characteristic “click” sound informs, that the filter
cover has been properly installed.
Do not use the vacuum cleaner with no inlet
and outlet filters mounted in the device.
Damaged inlet and outlet filters must be always
replaced with new, factory original filters.
THE CONE OF “CYCLONE” DUST CONTAINER
It is necessary to clean periodically the “CYCLONE” dust
container cone.
1
Disassembly “CYCLONE” dust container according to
point
(C)
.
E
F
Содержание Quigo zvc 315 SK
Страница 25: ...31 ZVC315 002_v01 Zelmer Zelmer 8 230 16 A RU...
Страница 27: ...33 ZVC315 002_v01 23 T B 1 2 3 4 5 6 3 7 8 4 9 4 10 9 4 1 5 5 2 4 3 4 5 7 16 6 7 8 a b c C...
Страница 29: ...35 ZVC315 002_v01 1 C 2 C 3 4 17 5 6 7 1 4 2 3 6 4 5 6 F G 7 8...
Страница 30: ...36 ZVC315 002_v01 K PE...
Страница 31: ...37 ZVC315 002_v01 Zelmer Zelmer 8 230 V 16 A BG...
Страница 33: ...39 ZVC315 002_v01 23 1 2 3 4 5 6 3 7 8 4 9 4 10 9 4 B 1 5 5 2 4 3 4 5 7 16 6 7 8 C...
Страница 35: ...41 ZVC315 002_v01 1 2 3 4 17 5 6 7 1 4 2 3 6 4 c 5 F G 6 7 8...
Страница 36: ...42 ZVC315 002_v01...
Страница 37: ...43 ZVC315 002_v01 Zelmer Zelmer 8 230 16 A UA...
Страница 39: ...45 ZVC315 002_v01 B 1 2 3 4 5 6 3 7 8 4 9 4 10 9 4 C 1 5 5 2 4 3 4 5 7 16 6 7 8 a...
Страница 41: ...47 ZVC315 002_v01 1 C 2 3 4 17 5 6 7 1 4 2 3 6 4 5 6 7 F G 8 a...
Страница 42: ...48 ZVC315 002_v01 PE 26663 19848 5 40 1 15150...
Страница 63: ...Notes...
Страница 64: ...Notes...