66
ZVC315-002_v01
9
Vacuum cleaner is equipped with electronic power
regulator, which - during the vacuuming - can smooth control
the suction power of vacuum cleaner. By turning the knob
(4)
right or left – you can increase or decrease the suction
power.
10
Vacuum cleaner is also equipped in mechanical control
of suction power
(9)
, which is located on the handle of the
hose. It can temporarily slightly adjust the suction power,
without adjustment done with knob
(4)
.
Disassembly/assembly of “CYCLONE”
dust container
Vacuum cleaner is equipped in removable dust container
“CYCLONE” (which is a removable segment of vacuum
cleaner), which accumulates contaminants. As soon as the
“CYCLONE” dust container is full, it should be emptied.
Vacuum cleaner is equipped with a safety
valve which is located in the chamber of the
“CYCLONE” dust container. The valve is
activated (open) automatically when a total
jam (occlusion) occurs on the sucking hose
or this happens to equipment connected to it,
as well as in the case of excessive overfill of
“CYCLONE” dust container. When the valve
is open you can hear a characteristic sound
(“a sound of flutter”) in the vacuum cleaner.
1
Vacuum cleaner is equipped with a dust container
“CYCLONE” full indicator
(5)
. When the gap of dust container
“CYCLONE” full indicator is totally filled with red mark during
operation (vacuum cleaner operates at full power and
sucker nozzle or brush is upraised over cleaned surface)
so this informs that there is a need to empty the dust bin
“CYCLONE”. The dust container “CYCLONE” full indicator
(5)
may work also in the case of clogging of the suction hose
or clogging of equipment connected to the hose.
2
Switch off the vacuum cleaner by pressing On/Off
button
(4)
.
3
Take off the cable connection plug from the wall outlet.
4
Press the two side buttons on the hose end, then remove
the hose end from vacuum cleaner inlet hole.
5
Raise the hook to unlock the dust container “CYCLONE”
(7)
and remove dust container “CYCLONE”
(16)
from the
vacuum cleaner.
6
Move the dust container “CYCLONE” on garbage trash.
Press the button located on dust container “CYCLONE”, the
bottom of the container will open and the contents will fall out
to the trash.
7
After emptying the container, snap the bottom. Pay
attention to the fact that a seal located on the bottom of
container must be correctly positioned.
Container must be precisely closed. Otherwise
the dust will penetrate the vacuum cleaner
chamber and the suction power will decrease.
C
8
Insert the empty dust container “CYCLONE” to vacuum
cleaner. The characteristic “click” indicates that container
has been mounted correctly.
Emptying the dust container “CYCLONE” is necessary when
you notice that:
a) “CYCLONE” dust container full indicator indices turned on,
b) sucking power of vacuum cleaner decreased,
c) dust container “CYCLONE” is full.
Disassembly of filters
In case of dirty filters: inlet filter, foam filter (15),
HEPA H13 inlet filter (14), outlet foam filter (13),
“Microfilter” (12) you can replace them with new
filters, clean them or rinse with running water.
Do not wash the filter in the washing machine
or dishwasher.
Filters can be dried in natural way only.
Do not dry the filters using hairdryers,
on heaters and radiators.
Before replacement of filters make sure that
vacuum cleaner is switched off and connection
cable plug is pulled out from the wall outlet.
INLET FILTER HEPA H13 AND FOAM INLET FILTER
It is necessary to clean periodically the inlet filter HEPA H13
(14)
in order to remove minor fractions of the dust, and foam
inlet filter
(15)
must be also cleaned.
Disassembly the “CYCLONE” dust container and empty it in
accordance with paragraph
(C)
.
1
Remove the HEPA H13 foam inlet filter
(14)
from
“CYCLONE” dust container.
2
Remove foam inlet filter
(15)
. If the foam inlet filter
(15)
is dirty, you can replace it with a new filter, you can clean
it or rinse with running water. Do not forget to dry above
mentioned filter before re-installation.
The main function of the foam inlet filter
(15)
is to protect
HEPA H13 inlet filter
(14)
against excessive dirt.
For safety reasons it is unacceptable to install
the moist or damaged foam inlet filter (15).
●
Clean the pleats of HEPA H13 inlet filter
(14)
, in case
of filter damage it should be absolutely replaced with
a new filter. If HEPA H13 inlet filter
(14)
is dirty, you can
replaced it with a new filter, you can clean it or rinse with
running water. Do not forget to dry above mentioned filter
before re-installation.
For safety reasons it is unacceptable to install
the moist or damaged inlet filter HEPA H13 (14).
●
Insert a new/rinsed inlet foam filter
(15)
into previously
occupied space.
3
Insert a new/rinsed HEPA H13 inlet filter
(14)
to the dust
container into previously occupied space.
D
Содержание Quigo zvc 315 SK
Страница 25: ...31 ZVC315 002_v01 Zelmer Zelmer 8 230 16 A RU...
Страница 27: ...33 ZVC315 002_v01 23 T B 1 2 3 4 5 6 3 7 8 4 9 4 10 9 4 1 5 5 2 4 3 4 5 7 16 6 7 8 a b c C...
Страница 29: ...35 ZVC315 002_v01 1 C 2 C 3 4 17 5 6 7 1 4 2 3 6 4 5 6 F G 7 8...
Страница 30: ...36 ZVC315 002_v01 K PE...
Страница 31: ...37 ZVC315 002_v01 Zelmer Zelmer 8 230 V 16 A BG...
Страница 33: ...39 ZVC315 002_v01 23 1 2 3 4 5 6 3 7 8 4 9 4 10 9 4 B 1 5 5 2 4 3 4 5 7 16 6 7 8 C...
Страница 35: ...41 ZVC315 002_v01 1 2 3 4 17 5 6 7 1 4 2 3 6 4 c 5 F G 6 7 8...
Страница 36: ...42 ZVC315 002_v01...
Страница 37: ...43 ZVC315 002_v01 Zelmer Zelmer 8 230 16 A UA...
Страница 39: ...45 ZVC315 002_v01 B 1 2 3 4 5 6 3 7 8 4 9 4 10 9 4 C 1 5 5 2 4 3 4 5 7 16 6 7 8 a...
Страница 41: ...47 ZVC315 002_v01 1 C 2 3 4 17 5 6 7 1 4 2 3 6 4 5 6 7 F G 8 a...
Страница 42: ...48 ZVC315 002_v01 PE 26663 19848 5 40 1 15150...
Страница 63: ...Notes...
Страница 64: ...Notes...