
53
VC1006-003_v01
7
Pull the plug and cord
(3)
out of the vacuum cleaner. Do it
smoothly (do not tug) to avoid cord tangling and blocking in
the vacuum body.
While puling out the cord pay attention to the
yellow stripe which signals the end of the cord.
Further attempts (pulling on cord) may result in
damaging the cord.
8
Plug in the appliance.
Before operation make sure that the SAFBAG bag is installed
in the vacuum cleaner chamber and that inlet filter and the
HEPA outlet filter is installed in the appliance.
9
Switch on the vacuum cleaner by pressing the “on/off”
button
(8)
.
10
The vacuum cleaner is equipped with electronic power
regulator allowing a stepless regulation of vacuum cleaner
power. The power regulation is performed with a slider.
Moving the slider right or left will increase or reduce
the suction power.
The following slider positions are recommended:
– for delicate fabrics such as curtains, etc.
– for upholstered furniture
– for carpets and floor coverings
– for hard surfaces such as floor, tiles,
parquet etc.
The power may also be adjusted individually depending on
the type of surface, vacuum effectiveness and suction power
of the switchable combination brush.
11
The vacuum cleaner is equipped with the “Parksystem
Auto-Start” function (available only in models VC1006.0HT,
VC1006.0ST and VC1006.0HP). It allows to switch the
appliance for a short time using the fastening hook of
the combination brush, without having to use the on/off
button. To do so, while the vacuum cleaner is in operation
insert the fastening hook of the combination brush to the
combination brush fastener
(2)
(the vacuum cleaner must be
in a horizontal position). The vacuum cleaner will be switched
off automatically.
12
The vacuum cleaner is also equipped with a mechanical
suction power regulator
(11)
located on the suction hose
handle. It can be used to adjust the suction power slightly for
a short time without having to use the slider
(6)
.
Filter disassembly
Before changing the filters make sure that the vacuum cleaner
is switched off and unplugged from the mains supply.
INLET FILTER
1
Release the catch of front cover
(10)
and open it.
2
Remove the SAFBAG dust bag module from the vacuum
cleaner chamber.
C
3
Put out the cover of inlet filter together with installed inlet
filter from the guide rails located on back wall of vacuum
cleaner chamber.
4
Take out the inlet filter from the inlet filter cover.
5
Put the new filter into inlet filter cover
(17)
. Pay attention
whether the edges of filter cling closely to the cover of filter.
6
The cover of inlet filter
(17)
together with installed filter
press home into guide rails to the previous location.
The damaged inlet filter should be replaced
with a new, genuine manufactured product
only.
7
Insert the SAFBAG dust bag module to the vacuum
cleaner chamber.
8
Close the cover by pressing it until you hear
a characteristic click – pay attention not to trap the dust bag.
HEPA OUTLET FILTER
The vacuum cleaners are equipped with a H11/H13 class
HEPA outlet filters.
HEPA filters are high-quality filters produced from special
fibres which are able to stop almost all dust particles.
The H11/H13 class indicates the permeability of the filter.
The H11 HEPA filter stops 95% of particles as small as 0.3
micron, and the H13 HEPA filter stops as much as 99.95%
of all impurities.
1
In order to replace the HEPA filter, press the blocking
mechanism of the outlet filter cover and slide up the cover of
the vacuum cleaner.
2
Remove the HEPA filter cassette and replace it with
a new one. The HEPA filter assures circa 1 year of effective
usage.
3
Slide the outlet filter cover back on in such a way that the
fastenings on the side of the cover fit into the sliders in the
vacuum cleaner housing. The filter cover fastening should
close.
SAFBAG dust bag disassembly/assembly
E
1
The vacuum cleaner is equipped with safety valve located
in chamber of dust container (bag). It opens automatically
in case of total stopping of suction hose or total stopping of
equipment elements connected thereto, as well as in case
of overfill of dust bag. After opening the valve one can hear
characteristic “whirr” sound inside the vacuum cleaner.
2
When the “Dust bag full” indicator light
(7)
comes on
when the nozzle or brush is above the floor, it indicates that
the bag needs to be replaced. The “Dust bag full” indicator
light may come on when the suction hose or connected
accessories become clogged.
3
Switch off the vacuum cleaner by pressing the on/off
button
(8)
and unplug the appliance.
4
Press the two side buttons on the end of the hose and
remove the hose end from the inlet opening of the vacuum
cleaner.
D
Содержание Flooris
Страница 27: ...31 VC1006 003_v01 Zelmer Zelmer 230 V 16 A 8 8 16 A ZELMER LVD 2006 95 EC EMC 2004 108 EC max 78 dB A CE RU...
Страница 31: ...35 VC1006 003_v01 K PE Zelmer 24 ZELMER 1 8 2 3 1 4 5 A 6 7 8 G...
Страница 32: ...36 VC1006 003_v01 Zelmer Zelmer 230 V 16 A 16 ZELMER LVD 2006 95 EC EMC 2004 108 EC 78 dB A CE BG...
Страница 36: ...40 VC1006 003_v01 Zelmer 24 ZELMER 1 8 2 3 1 4 5 A 6 7 8 G...
Страница 37: ...41 VC1006 003_v01 Zelmer Zelmer 230 V 16 A 8 8 16 A ZELMER LVD 2006 95 EC EMC 2004 108 EC max 78 dB A CE UA...
Страница 41: ...45 VC1006 003_v01 PE 26663 19848 5 40 1 15150 4 5 A i 6 7 8 a 300 36 060...
Страница 42: ...46 VC1006 003_v01 Zelmer Zelmer 16 230 ZELMER 8 8 KZ...
Страница 46: ...50 VC1006 003_v01 BNB 19 Zelmer 24 Zelmer 1 8 2 3 1 4 5 6 7 8 G...