A Micro Data Centre is a standalone housing unit that replicates

!

all of the cooling, security and power capabilities of a traditional

!

data center on a much smaller, lower cost scale. It miniaturizes

!

the data centre into the size of an average refrigerator, offering its

!

own cooling and power capabilities, significantly reducing operational

!

and energy costs by 30-60%, and on-premise IT footprint. Moreover,

!

it allows for portability and can be moved from location to location,

!

and expanded to a set of 

ʻ

modular

ʼ

 data centers as business grow.

!

!

The micro data centre is a self-contained facility designed to house

!

your critical networking equipment and to provide the infrastructure

!

of a conventional server facility in a portable and robust environment.

!

The Micro Data Centre eliminates the need for a server room.

!

!

Our micro data centres offer a robust and dependable answer to the

!

question of housing and securing your networking and data storage

!

equipment. The facility, in the form of a cabinet, has a host of built-in

!

features, which ensure that your server is secure, accessible and fully

!

portable.

!

!

The Micro Data Centre can accommodate your requirements based

!

on a plug-and-play operation of any of the following components:

!

!

The Micro Data Centre is available in two models namely; Cubb® and

!

Cubb®Duo. The Cubb is a single cooling unit and the CubbDuo is a

!

dual cooling unit.

!

Zellabox 

Introduction 

      

      

      

   

1

 

Introduction 

Power Distribution Unit

!

Internal Cooling System

!

Uninterrupted Power Supply (Rack 

mounted up to 6000 VA)

!

Access Control System (Code / Card /

Biometric)

!

Environmental Monitoring

!

Automated Fire extinguishing System

!

Cabinet Lighting

!

Cable Management System

!

Содержание Cubb

Страница 1: ...1 Zellabox User Manual...

Страница 2: ...2 Pyrorack 2 3 Uninterruptible Power Supply 2 4 Switchboard 3 Start up procedure 4 Technical Data 4 1 Access Control 4 2 Pyrorack 4 3 Uninterruptible Power Supply 4 4 Switchboard 4 5 Cooling System 4...

Страница 3: ...nd robust environment The Micro Data Centre eliminates the need for a server room Our micro data centres offer a robust and dependable answer to the question of housing and securing your networking an...

Страница 4: ...ructions 2 1 Overview Important safety note Caution needs to be taken when removing the side panels of the Micro Data Centre in particular when dealing with the 38U as they are heavy we recommend a 2...

Страница 5: ...ted Avoid exposure to the fire by products and extinguishing mixture Should it be necessary to enter the area before it is fully ventilated the use of a respirator or other means of protection may be...

Страница 6: ...p on or trip over them Do not connect domestic appliances such as hair dryers to UPS output sockets The UPS can be operated by any individuals with no previous experience Connect the UPS system only t...

Страница 7: ...e take the precautionary measures specified below and any other measures necessary when working with batteries Remove wristwatches rings and other metal objects Use only tools with insulated grips and...

Страница 8: ...DO NOT exceed the cooling system s recommended BTU h specifications listed in the cooling system section as this will overheat the equipment The Zellabox Micro Data Centre is a PLUG N PLAY unit theref...

Страница 9: ...nt panel indicators will be as follows Mode Indicator Door Indicator 9 Zellabox Technical data 4 Technical data 4 1 Access control 4 1 1 Metal Keypad Key Features 500 Users Water and vandal resistant...

Страница 10: ...Water and vandal resistant Backlight Backlit family option B Three user levels normal secure master Three modes of operation normal bypass secure Integrated keypad for PIN entry Piezo electric Q44 on...

Страница 11: ...irements The installation of this product should only be carried out by a competent person and comply with applicable current National or International standards 11 Zellabox Technical data 4 2 Pyrorac...

Страница 12: ...base correctly also check that the end of line resistor is in place on the detector base 4 2 3 3 System Fault Cause see all other Fault Indications and Detectors Remedy Check Detectors in place and p...

Страница 13: ...t every 3 months the following checks are carried out by a competent person Entries in the Log Book are checked and any necessary action taken Batteries and their connections should be examined and te...

Страница 14: ...Zellabox Technical data 4 3 Uninterruptibale power supply 4 3 1 Introduction Please refer to relevant UPS User Manual provided in the Zellabox or alternatively go online 14...

Страница 15: ...res Functions The switchboard is plugged or hardwired directly into the building s power source and has a green light on the front panel which MUST be illuminated at all times indicating there is a po...

Страница 16: ...but rather switching the cooling system off at the switchboard to reset the controls The recommended temperature setting is between 20 and 23 degrees for maximum efficiency Problem Potential Cause So...

Страница 17: ...ratures over 42 degrees within the data centre while a cooling unit is running the alternate unit will start up and provide extra cooling for the Micro Data Centre Once the temperature drops below 20...

Страница 18: ...ffer a simple user experience for seamless physical deployment configuration commissioning monitoring and power delivery Zellabox power distribution hardware will remain in place through multiple tech...

Страница 19: ...19 Zellabox Zellabox Pty Ltd PO Box 1035 Osborne Park DC Western Australia 6916 AUSTRALIA 1300 117 644 www zellabox com info zellabox com Version 2016 007...

Отзывы: