NOTES ON INSTRUMENT SAFETY 

VivaTome 

Safety Notes 

Carl Zeiss 

 

 
 

M60-2-0046 e   05/2012 

423639-9000-701 

1.2

 

Safety Notes 

VivaTome including its original accessories must not be used for applications other than those described 
in the present operating manual. 
Please observe the following warnings: 

 

Follow the instructions given in the manufacturers' operating manuals of the HXP 120 and 

VivaTome! 

 

 

Observe the operating manual of the microscope in use to ensure reliable functioning of the 

illumination system in combination with the microscope. 

 

 

Use the instrument for Carl Zeiss microscopes only.   
The manufacturer cannot assume any liability for other applications, including those of 

individual modules or single components. This also applies to any service or repair work that is 

not carried out by authorized service personnel. In case of non-compliance, all warranty claims 
shall be forfeited. 

 

 

 

 

Do not operate the device and the accessories included in the delivery in potentially explosive 

areas, in the presence of volatile anesthetics or flammable solvents, such as alcohol, benzine or 
similar chemicals. 

 

 

The VivaTome power supply unit is classified as a protection class II unit (with protective 

insulation) and must not get in contact with moisture. If its casing is damaged, put the power 
supply unit out of operation. 

 

 

 

 

The instrument is not equipped with special devices for the protection from substances that are 
corrosive, potentially infectious, toxic or radioactive, or from other substances that could be 

hazardous to health. Make sure to observe all legal requirements, particularly the relevant 
national accident prevention regulations when handling such substances. 

 

 

 

 

If equipped with a white light source coupled by a liquid light guide, the instrument emits 

ultraviolet radiation that may cause burns to the eyes and skin. Therefore, never look directly 

into the light and avoid direct incidence of the light on your skin. When operating the 
microscope, always use the protective devices belonging to the instrument. 

 

 

 

 

Never look into the light beam - neither with nor without optical instruments, even not if you 
simply want to observe the specimen. Your eyes may be damaged in case of non-observance! 
 

Содержание VivaTome

Страница 1: ...VivaTome Operating Manual...

Страница 2: ...d by an update service Unless expressly authorized forwarding and duplication of this document as well as utilization and communication of its contents are not permitted Violations will entail an obli...

Страница 3: ...12 2 5 Technical Data 13 3 START UP 15 3 1 Installation Requirements 15 3 2 Requirements as to the Microscope Stand 16 3 3 Basic Microscope Settings 17 3 4 Mounting VivaTome 17 3 5 Mounting Supportin...

Страница 4: ...you recognize at a glance the type and purpose of the notes included in this operating manual CAUTION This symbol indicates a possible hazard to the user of the instrument CAUTION Do not look into the...

Страница 5: ...he presence of volatile anesthetics or flammable solvents such as alcohol benzine or similar chemicals The VivaTome power supply unit is classified as a protection class II unit with protective insula...

Страница 6: ...urce has to be changed according to the manufacturer s operating instructions of the white light source Otherwise there is danger of burns and explosion when changing the bulb Maintenance or repair wo...

Страница 7: ...for at least five minutes If the irritation persists consult a medical specialist Proper disposal of Immersol 518 F Take care to ensure that it does not enter surface water or the sewage system Do not...

Страница 8: ...mize damage If notified of such a defect the manufacturer is obligated to rectify it at its discretion either by repairing the instrument or by delivering an intact replacement No guarantee is provide...

Страница 9: ...focus The emission light from the specimen is detected again through the same disk In VivaTome highest light efficiency is of utmost importance The structure of the VivaTome spinning disk allows up t...

Страница 10: ...es the second simultaneously detected image which was reflected from the disk and thus contains out of focus intensities An optical section is obtained by simple scaled subtraction of both images imag...

Страница 11: ...working memory Monitor for image display Digital camera AxioCam MRm AxioCam HRm AxioCam EM Image editing software AxioVision minimum Rel 4 8 Vibration damped table or anti vibration plate Axio Observ...

Страница 12: ...DESCRIPTION Carl Zeiss System Overview VivaTome VivaTome 12 423639 9000 701 M60 2 0046 e 05 2012 2 4 System Overview VivaTome Fig 2 2 System overview...

Страница 13: ...emperature 10 to 50 C Admissible air humidity no condensation 20 to 75 at 35 C Atmospheric pressure 800 to 1060 hPa Operation Admissible ambient temperature 10 to 35 C Admissible relative humidity 20...

Страница 14: ...requency 50 60 Hz Maximum power consumption max 210 VA Fuses 2x T 2 5 A H Environment for use closed rooms Protection class I Protection type IP 20 Electrical safety in compliance with DIN EN 61010 1...

Страница 15: ...ting air cushioned microscope stage Power Requirements Two additional wall outlets are required to connect the system VivaTome and HXP 120 Ambient Conditions 1 Operation specified power T 22 C 3 C wit...

Страница 16: ...to the intended use Any use of VivaTome in combination with microscope stands having an order number other than that indicated in the present manual is not in accordance with the intended use Set up t...

Страница 17: ...a sheet 3 4 Mounting VivaTome The white light source must not be switched on until after having connected the output of the liquid light guide tightly with VivaTome and VivaTome firmly screwed to the...

Страница 18: ...2 2 into VivaTome as far as it will go Now screw the supporting feet in or out to the required height Turn the counternut Fig 3 2 3 downwards to secure the supporting foot 3 6 Mounting the Camera The...

Страница 19: ...me Connect the VivaTome power supply unit with a mains socket outlet Connect the DC output of the power supply unit to the socket Fig 3 5 2 on the back of the device Insert the liquid light guide into...

Страница 20: ...tch Fig 4 1 1 Grid pattern selection switch Fig 4 1 2 Switch over between the two grid patterns Filter selection switch Fig 4 1 3 Switch over between different filters Shutter pushbutton Fig 4 1 4 To...

Страница 21: ...let As the filter module and the camera adapter are properly matched to one another they must always be changed jointly Filter sets and camera adapters which belong together have the same ID number Ch...

Страница 22: ...he two guide bolts make insertion easier Unscrew the two fastening screws from the threaded holes of the filter module Introduce the three fastening screws Fig 4 3 1 into the filter module Fig 4 3 2 a...

Страница 23: ...urfaces Use a clean cloth moistened with water that may contain a mild detergent Take care that no moisture enters the instruments Do not use any solvents Dry cleaned surfaces with a lint free cloth C...

Страница 24: ...elect camera port No free passage in the reflector turret Select empty position in the reflector turret 5 4 Service Request Any interventions to mechanical optical and electronic components inside the...

Отзывы: