2.5
Technical Data
Dimensions of VivaTome (W x D x H) ................................................ approx. 280 mm x 150 mm x 70 mm
Dimensions of power supply unit (W x D x H) ..................................... approx. 120 mm x 55 mm x 40 mm
Dimensions of HXP 120 / HXP 120 C (W x D x H) ............................ approx. 130 mm x 210 mm x 290 mm
Weight of VivaTome ...................................................................................................................... 6.4 kg
Weight of power supply unit .......................................................................................................... 0.2 kg
Ambient conditions
Transportation and storage (in packaging)
Admissible ambient temperature ........................................................................................ -10 to +50 °C
Admissible air humidity (no condensation) ............................................................ 20 % to 75 % at 35 °C
Atmospheric pressure .................................................................................................... 800 to 1060 hPa
Operation
Admissible ambient temperature ....................................................................................... +10 to +35 °C
Admissible relative humidity ................................................................... 20 % to 80 %, no condensation
Atmospheric pressure ..............................................................................................800 hPa to 1060 hPa
Pollution degree ................................................................................................................................... 2
Operating data
VivaTome
Supply voltage ....................................................................................................... 12 V DC; max. 1.25 A
Power supply unit VivaTome
Line voltage ........................................................................................................ 100 to 240 VAC
±
10 %
Change of line voltage unnecessary!
Line frequency ........................................................................................................................... 50/60 Hz
Power consumption of power supply unit .................................................................................... 400 mA
Output voltage ......................................................................................................... 12 VDC; max. 1.3 A
Environment for use ............................................................................................................closed rooms
Protection class ...................................................................................................................................... II
Protection type ................................................................................................................................. IP20
Electrical safety ........................................................................................ in compliance with EN 61010-1