background image

VICTORY RF OWNER’S MANUAL - NORTH AMERICA | 

17

16

 | VICTORY RF OWNER’S MANUAL - NORTH AMERICA

For the latest updates and information regarding our products, visit zeiss.com/us/sportsoptics.

• 

Bluetooth-connectivity – synced to ZEISS Hunting App (ZHA)

•  Range 11 to 2,500 yards
•  Custom ballistic input via smartphone or tablet
•  B.I.S. II – Onboard ballistic calculator with integrated sensors  

and ballistic profiles 

•  Measures angle, temperature and air pressure
•  Calculates equivalent horizontal distance
•  Displays holdover in inches/cm, MOA, MIL and clicks
•  Features Scan and Target modes

•  Automatic LED brightness adjustment (11 brightness curves) 
• 

User-programmable control buttons and display  

• 

One-touch ranging (right or left hand)

• 

Syncs personal settings and ballistic profiles to and from the RF

•  Superior image quality, enhanced by FL glass, ZEISS T* and LotuTec coatings 
• 

Compact, lightweight and user-friendly ergonomics 

•  Large focusing wheel for minimal rotation
• 

High-grade magnesium frame with double-link bridge 

•  Rugged and waterproof
•  Remote software updates via Bluetooth and ZEISS Hunting App

1.  First, ensure you have your mobile device and the ZEISS Victory RF 

in the same work area. ZEISS recommends a clean work area for the 
initialization process in order to support each item as well as the 
connecting instructions. The complete initial sync and data input process 
should take less than 30 minutes. 

2.   Next, you will need to download the ZEISS Hunting App (ZHA) from 

either Google Play or the App Store – depending upon your device  
(smartphone, tablet, etc). 
 

a. The ZHA is free, and it offers several other benefits for the hunter 

 

  and shooter. 
   
b. The ZHA allows for easy Victory RF (VRF) support, setup, and  

  syncing of your data for a positive field-use experience.

 

   
c. While the VRF menus can be accessed and manipulated as  

  an on-board option, the ZHA provides a faster, easier, and 

 

  friendlier platform to input and update relevant data and settings  
  into the VRF model. 

ESTABLISHING A CONNECTION BETWEEN

THE ZEISS HUNTING APP AND ZEISS VICTORY RF

6 | 7 

EN

Turn off

You can turn off your ZEISS Victory RF menu by pressing the range finding button in 
menu 7 (press SET button for 2 s press the SET button six times).
There are two other ways to shut down your ZEISS Victory RF. Either hold the SET 
button down for 2 seconds or don‘t press either of the buttons for around 10 
seconds. 

Adjustment with the ZEISS Hunting APP

With the ZEISS Hunting App, you have the option of carrying out all the adjustments 
mentioned above with your smartphone, in a simple and user-friendly way.
You also have the option of making two further, personalised adjustments. Firstly, 
you can enter your own ballistics profile, created in the ZEISS Hunting App, and you 
can also set up to three different displays in the display settings.

ESTABLISHING A CONNECTION BETWEEN 
THE ZEISS HUNTING APP AND ZEISS VICTORY RF

Initial Connection

When you first want to connect your ZEISS Victory RF, „Connect Your ZEISS Product“ 
will appear on the screen in the Connected Products section 

(Fig. 10)

. By clicking 

the Connect Button once, your ZEISS Hunting App begins connection set-up. 
As described in 

Fig. 11

, you must then hold the SET button down for only 

10 seconds. 
Then, the word „CON_“ appears on your ZEISS Victory RF. After you release the SET 
button, the word „PAIr“ appears on the display and you confirm this by pressing the 
measuring button once. 
Now your ZEISS Victory RF is connected with your ZEISS Hunting App as shown in 

Fig. 12

. You 

only

 need to confirm the „PAIr“ 

for your first

 connection.

Repeated Connection

After you have initially connected your ZEISS Victory RF with your ZEISS Hunting 
App, the Start screen changes the Connected Product Section, as shown in 

Fig. 13

Above the (+) button on the bottom right, you can connect ZEISS Victory RF with 
your ZEISS Hunting App again. Furthermore, by simply clicking on the stored ZEISS 
Victory RF you can make adjustments on your device 

(Fig. 14)

 and then sync these.

MAKING ADJUSTMENTS

Ballistics Settings

In the ballistics settings 

(Fig. 15)

 in your ZEISS Hunting App, as well as selecting 

the nine standard profiles, you also have the option of adding up to nine more 
personalised profiles and subsequently syncing with your ZEISS Victory RF. To add 
a personalised profile, click on the button „Add Profile“ in the ballistics menu. Then 
you can select all previously created ballistics profiles (you can create these in the 
„Ballistics“ section of the Toolbox) 

(Fig. 16)

.

You also have the option of setting one of your profiles as a „favourite“. The 
favourite is the setting that is active on your ZEISS Victory RF and is indicated by a 
blue star.

In the ZEISS Hunting App display settings 

(Fig. 17)

, as well as the choice of the seven 

standard profiles, you have the option of adding up to three more personal profiles 
and subsequently syncing them with your ZEISS Victory RF. To add a personal profile, 
click on the button „Add Configuration“ in the ballistics menu. Unlike the standard 
profiles 

(Fig. 18)

, you can combine up to three display modes in your personal 

profiles. Here, the distance is always set as the first display mode. 
You also have the option to save one of your configurations as a „favourite“. The 
favourite is the setting that is active on your ZEISS Victory RF and is indicated with a 
blue star.

Fig. 10

Fig. 14

Fig. 11

Fig. 15

Fig. 12

Fig. 16

Fig. 13

Fig. 17

iOS / Android 

Compatible

Continued on following page.

(The screenshots herein are depicted as accurately as possible at time of print. The ZEISS Hunting App 

may be updated from time to time, which may reflect a difference in the screen image illustrated.)

(Illustrative examples were captured on an iPhone for the purpose of reference.)

Содержание VICTORY RF Series

Страница 1: ...vered by one or more of the following United States patents US6542302 US6816310 US6906862 For further United States patents which may cover this product see www zeiss com sports optics us patents PRECISION RANGEFINDERS FOR YOUR HUNTING AND SHOOTING ADVENTURES 8x54 10x54 8x42 10x42 ...

Страница 2: ...llustration purposes only 2 VICTORY RF OWNER S MANUAL NORTH AMERICA ZEISS Sports Optics is not responsible for typographical errors Product images are for illustration purposes only Specifications and products may change without prior written notice All efforts have been made to make sure content is accurate at time of printing IDENTIFICATION OF THE COMPONENTS 1 Eye cup 2 Central focusing 3 Diopte...

Страница 3: ... Never leave the binoculars in the sun for extended periods of time without the protective lens cap in place The objective lens and eyepiece can function as a burning glass and damage the interior components DANGER OF SWALLOWING Caution Do not leave the batteries and removable exterior parts within reach of children danger of swallowing Further information and safety instructions can be found in t...

Страница 4: ... and debris have not contaminated the battery compartment or threads of the compartment and battery cover align and tighten the cover by turning it clockwise taking care not to cross the threads Turn the cover until it stops in order to ensure a snug fit and waterproofness NOTE At 68 F a new battery will last for over 2 500 measurements However depending on the conditions of use such as low temper...

Страница 5: ...ue to secure the eyecup to the ocular housing The eyecups are ready for regular adjustments at this time Focusing the aiming mark and diopter compensation Use the range finder button Fig 1 6 to switch on the aiming mark Fig 2 9 and hold down the button Focus the aiming mark and the display by turning the right hand diopter compensation Fig 1 4 to the left or the right Then carefully use Fig 8 2 4 ...

Страница 6: ...nu options by pressing the SET button once for each option NOTE See Options Table 1 BRIGHTNESS There are 11 brightness settings in the ZEISS Victory RF They are located in Menu 1 press the SET button Fig 1 7 for 2 seconds By pressing the range finding button Fig 1 6 you can select one of the 11 different brightness settings Setting 1 darkest setting possibility Setting 11 brightest setting possibi...

Страница 7: ...ation System B I S II is not to be used as a replacement for the hunter s shooter s assessment of the actual shooting environment but rather to support and increase safe shooting ZEISS recommends shooting exercises from different ranges which can be used to check the correct match of the specifications with the actual points of impact also referred to as trajectory validation TABLE 2 Relates to th...

Страница 8: ...u can always display the saved settings in the menu Unit Choose the appropriate unit in Menu 4 press the SET button for 2 seconds press the SET button three times Measuring Mode You can select the appropriate measuring mode for you in menu 5 press the SET button for 2 seconds press the SET button four times You can select whether you are shown the best measurement tA b or the furthest measurement ...

Страница 9: ...rt setup and syncing of your data for a positive field use experience c While the VRF menus can be accessed and manipulated as an on board option the ZHA provides a faster easier and friendlier platform to input and update relevant data and settings into the VRF model ESTABLISHING A CONNECTION BETWEEN THE ZEISS HUNTING APP AND ZEISS VICTORY RF ESTABLISHING A CONNECTION BETWEEN THE ZEISS HUNTING AP...

Страница 10: ...for input NOTE ZEISS strongly suggests the validation of muzzle velocity via a quality chronograph Muzzle velocity listed on some ammunition is for a specific barrel length within a controlled environment and does not factor in the many variables that are associated with obtaining true muzzle velocity through your rifle 3 Once the ZEISS Hunting App is downloaded you will need to pair the mobile de...

Страница 11: ...t which you select the display data that you want to see while in the field The VRF will display these three pieces of data in the order you have selected for input Fig 15 1 The first piece of data defaults to RANGE 2 You can then select the other data from the menu options Many people like to select one of the various Holdover options ZEISS strongly suggests choosing the option that YOU are comfo...

Страница 12: ...ected ensure the load is highlighted with a blue star as illustrated Fig 17 NOTE The VRF model does not have to be connected to the ZHA in the field in order to work The VRF operates as a stand alone unit ESTABLISHING DEVICE SETTINGS 1 From the ZHA Dashboard select the Connected Products tab Notice the ZEISS Victory RF model with serial number Then select Device Settings Fig 16 a From here you can...

Страница 13: ...ERS ARE IN PLACE FIRST These types of cleaning solvents can and will destroy the fine and precision multi layer lens coatings Cleaning Your Lenses ZEISS recommends using original ZEISS branded lens cleaning solutions supplies and complete cleaning kits to care for the lenses on your VRF First permit heavy or large debris on the lens surfaces to fall away from the surface Try to carefully remove lo...

Страница 14: ...ts Please send to ZEISS Authorized Distributor Gentec 90 Royal Crest Court Markham Ontario CANADA L3R 9X6 P 905 513 7733 STOP Before sending a product in for service please call ZEISS Sports Optics Customer Care team at the number below in order to determine if the issue concern can be resolved without having to return the product 1 800 441 3005 repair sportsoptics zeiss com Please complete the on...

Страница 15: ... download the ZEISS Hunting App This free app offers useful unique and easy to use information at your fingertips Hunt longer Hunt better Hunt with confidence ZEISS 01 2020 SAP 000000 2285 607 Manual Victory RF Bluetooth Enabled Customer Service 1 800 441 3005 info sportsoptics us zeiss com Carl Zeiss SBE LLC Sports Optics Division zeiss com us sportsoptics JOIN THE CONVERSATION ...

Отзывы: