14
6.
Set the aperture of the Supreme Prime to full speed by rotating the aperture ring.
The aperture setting must not be changed during the adjustment process.
7.
Activate the live view of your camera.
8.
Select the maximum magnification of the live view.
9.
Make sure that the center of the image aligns with the center of the siemens star test chart.
10.
Set the focus ring according to the testing distance. See Shimming Table.
The focus setting must not be changed during the adjustment process.
11.
Obtain maximum image sharpness on the live view by varying the distance between the test chart and the camera.