Description 

The Vertical Illumination Device S is a very suitable accessory to illuminate objects extended in depth, such 

as bores, recesses and holes, due to the small angle between illumination and observation and the 
concentration of the light towards the field center. 
The  Vertical Illumination Device S  can be operated in combination with an existing standard cold-light 
source, preferably with the CL 1500 ECO. An optional, flexible light guide of 4.5 mm diameter is used to 

connect the Vertical Illumination Device S with the cold-light source. 
It can be combined with the objectives Plan S 1,0x, Achromat S 1,0x, Achromat S 0,63x, 

Achromat S 0,5x, PlanApo S 1,0x and PlanApo S 0,63x. 

 
 

Technical Data 

Dimensions (diameter x height) .......................................................................................... 79 x 24.5 mm 
Weight ..................................................................................................................................... 0.120 kg 
 

Ambient Conditions 

Transportation (in packaging): 

Admissible ambient temperature .................................................................................... -40 to +70 °C 

Storage: 

Admissible ambient temperature ................................................................................... +10 to +40 °C 
Admissible air humidity (no condensation) ............................................................ max. 75 % at 35 °C 

Operation: 

Admissible ambient temperature ................................................................................... +10 to +40 °C 
Admissible relative humidity (no condensation) ..................................................... max. 75 % at 35 °C 
Operation altitude .......................................................................................................... max. 2000 m 
Atmospheric pressure ......................................................................................... 800 hPa to 1060 hPa 
Pollution degree ............................................................................................................................... 2 
Environment for use ........................................................................................................ closed rooms 

 
 

Содержание SteREO Discovery Vertical Illumination Device...

Страница 1: ...Vertikalbeleuchtung S Vertical Illumination Device S Bedienungsanleitung Operating Manual...

Страница 2: ...Knowledge of this manual is required for the operation of the instrument Would you therefore please make yourself familiar with the contents of this manual and pay special attention to hints concernin...

Страница 3: ...lbeleuchtungen S d rfen nur f r die nachfolgend beschriebenen Zwecke verwendet werden Die Bedienungsanleitung des verwendeten Mikroskops SteREO Discovery ist zu beachten Schmutz und Staub k nnen das G...

Страница 4: ...iblen Lichtleiter mit Durchmesser 4 5 mm mit der Kaltlichtquelle zu verbinden Sie ist verwendbar f r die Objektive Plan S 1 0x Achromat S 1 0x Achromat S 0 63x Achromat S 0 5x PlanApo S 1 0x und PlanA...

Страница 5: ...tiv und Zoomstellung der Beleuchtungsspiegel bez glich Probenausleuch tung und Vignettierungsfreiheit optimiert werden Durch Verschieben der Schubstange Bild 2 3 den Beleuchtungswinkel des Spiegels Bi...

Страница 6: ......

Страница 7: ...Devices S is permitted only for the purposes described below Strictly observe also the operating manual of the microscope used SteREO Discovery Dirt and dust may impair the performance of the device I...

Страница 8: ...ide of 4 5 mm diameter is used to connect the Vertical Illumination Device S with the cold light source It can be combined with the objectives Plan S 1 0x Achromat S 1 0x Achromat S 0 63x Achromat S 0...

Страница 9: ...position of the illumination mirror to be optimized in dependence on the objective and zoom setting in order to obtain the appropriate illumination of the specimen and exclude vignetting For an optimu...

Страница 10: ......

Отзывы: