308721:020.24 /5
Fusible plugs T 200 (for net tension 240 V and 220 V) or 343.28
Fusible plugs T 400 (for net tension 110 V and 127 V) 343.30
(30) Symbols
switched off
at the Vergrößerungswechsler and/or at the Kontrasttubus: Objective lens 1/1.6 switching on
1x Tubuslinse (factor 1) switched on
│
switching on
│
at the Kontrasttubus: direct path of rays contrast loop switched on linkage for photo exit
Bertrandlinse switching on (31) unpacking and assembly
To foam material packing thus put tape to remove that the impressing are cash les. Covers take off.
Standard equipment JENAVAL contrast/GF Pa
Stand (fig. 1/10), light HS 25 Watts with intermediate optics, filter house and filter change-over switch (fig. 1/18, 15) as well as rear wall D
and lens turret (fig. 1/6) are already installed.
On this building group:
Vergrößerungswechsler (fig. 1/4) with Fototubus begin (fig. 1/3) according to illustration 1 from the top into the swallow guidance, until
attack forward draw and with wedge screws (fig. 2/21) fix (box spanners B use) fig. 6/58).
Kontrasttubus (fig. 5/45) according to illustration 4 and 5 from the top on in swallow guidance insert, to attack after in front-pulled and
with Klemmschrau fuel element (fig. 4/39) fix. (Box spanners B use) fig. 6/58).
Table carriers (fig. 6/29) according to illustration 3 from the top into the swallow guidance to attack push in and with clamping screw fix
(box spanner B, fig. 6/58).
Condensor lens guidance with Triebknopf (fig. 1/14) to attack off lower. Condensor lens A TRAILERs with the condensor lenses 0.9 and
0.12 (fig. 6/54) from left to the condensor lens guidance set, lower attack to mount let and with clamping screw (fig. 3/30) wedge.
Kreuztisch D (fig. 1/7) from on the right of ago into the swallow of guidance of the table carrier (fig. 3/29) begin, to attack to the left push
and with to the two clamping screws (fig. 3 28) fix (hexagonal wrenches (fig. 6/59) use). Condensor lens with Triebknopf (fig. 1/14) to
attack raise.
Objective ones screw in, favourably in such a way that with the rotation of the gun in the clockwise direction the next-stronger in
each case whether rests jektiv in working position; weakest objective in eye No. 1
Binokulartubus set and wedge; Eyepieces use, the placable eyepiece belonged in the right connecting pieces of the binocular tubus
Filters in filter change-over switch (fig. 6/15) use: Orient yourselves please with (2)
Left and right hand rest (fig. 6 and 1/11) on the foot of the microscope set and after your discretion align that focusing and table
impulses with comfortably resting upon hand serves become can.