INSTRUMENT DESCRIPTION
Axioskop 2
plus
Carl Zeiss
Technical data
Axioskop 2
mot plus
1-16
B 40-075 e 10/03
1.8
Technical Data
Dimensions (width x depth x height)
Axioskop 2
plus
/
mot plus
with phototube and HAL 100................ approx. 280 mm x 600 mm x 475 mm
Axioskop 2
plus
/
mot plus
with phototube and HBO 103 ............... approx. 280 mm x 733 mm x 475 mm
Axioskop 2
plus
/
mot plus
with ergo-phototube and HAL 100........ approx. 280 mm x 670 mm x 500 mm
Axioskop 2
plus
/
mot plus
with ergo-phototube and HBO 103 ....... approx. 280 mm x 800 mm x 500 mm
Weight
Axioskop 2
plus
.................................................................................................................approx. 18.4 kg
Axioskop 2
mot plus
..........................................................................................................approx. 22.4 kg
Ambient conditions
Transport (in packaging):
Permissible ambient temperature ..........................................................................................-40 to +70 °C
Storage:
Permissible ambient temperature .........................................................................................+10 to +40 °C
Permissible humidity (without condensation)............................................................... max. 75 % at 35 °C
Operation
Permissible ambient temperature ..........................................................................................+5 to + 40 °C
Permissible relative humidity ....................................................................................... max. 75 % at 35 °C
Altitude .................................................................................................................................max. 2000 m
Atmospheric pressure ................................................................................................800 hPa to 1060 hPa
Pollution degree ...................................................................................................................................... 2
Operating data
Operation..............................................................................................................................closed rooms
Protection class......................................................................................................................................... I
Enclosure protection .......................................................................................................................... IP 20
Electrical safety ................................................................ in compliance with DIN EN 61010 (IEC 61010-1)
including CSA and UL directives
Overvoltage category............................................................................................................................... II
Radio interference suppression ........................................................ in accordance with EN 55011, Class B
Noise immunity ...............................................................................in accordance with DIN EN 61326/ A1
Содержание Axioskop 2 mot plus
Страница 1: ...Operating Manual Axioskop 2 plus Axioskop 2 mot plus Routine Microscope...
Страница 68: ...START UP Axioskop 2 plus Carl Zeiss Axioskop 2 mot plus 2 36 B 40 075 e 10 03...
Страница 130: ...CARE MAINTENANCE TROUBLESHOOTING AND SERVICE Axioskop 2 plus Carl Zeiss Axioskop 2 mot plus 4 10 B 40 075 e 10 03...