Technical data

 

EN_20_012_0043l 

13

 

Technical data

 

Electrical power rating  

Rated voltage  

100 

 240 V AC ±10%  

Rated frequency  

50 

 60 Hz  

Protection class  

I  

Plug-in connection  

CEE 7/7 Hybrid  

Power consumption  

through 1,2 A  

 

Ambient conditions for the intended use

  

Temperature 

 

+10 °C 

 40 °C  

Humidity

  

10 % 

 90 % (non-condens-

ing)  

 

 

Dimensions and weights

  

Dimensions (height x width x 
depth)  

112 x 355 x 220 mm  

Weight  

4,7 kg  

 

Device type

  

Name  

ZEISS Server 

Model  

5034555 

 

Interface (front side)

  

Standby with LED status display 

1 x RGB-LED button 

Changeable frame  

1 x 3,5” SATA HDD for backup 

 

 

Interface (back side)

  

Monitor interface  

1x DVI-I  

LAN  

1x Gigabit Ethernet  

USB  

2x external USB 3.1 ports 
1x external USB 2.0 ports  

PS/2 

1x Mouse 
1x Keyboard 

DC-IN plug  

1x 12 V DC  

COM 

1x RS232 

 

 

 

Subject to change in design and scope as well as technical 
changes.  

 

 

  

 

Fig. 1: 

Type plate for ZEISS Server

 

 

Содержание 5034555

Страница 1: ...ZEISS Server User Manual Version 2 0...

Страница 2: ...nts do not lose validity in the event of changes to relevant laws or standards The user of the product is responsible for respecting all trademarks or existing laws Specifications are only binding whe...

Страница 3: ...Installation Position 4 4 Power supply 5 5 Ambient conditions 5 6 Expansion and Repairs 6 7 Maintenance 6 8 Battery 6 9 Additional safety instructions 6 10 Shutdown 7 11 Disposal 7 12 Other provisions...

Страница 4: ...be adjusted and remain constant A minimum distance of 100 mm from walls or other objects must be maintained in order to ensure sufficient ventilation Existing fan vents and cooling units in the housin...

Страница 5: ...t the power socket on the device or the line supply out let is freely accessible The device can be disconnected from the line supply by pulling the power cord For DC supply the power supply voltage in...

Страница 6: ...must be checked 1x per year 8 Battery The main board is fitted with a battery Only authorized technicians are per mitted to replace it There is a risk of explosion if the battery is replaced improper...

Страница 7: ...by the EMC directive 2014 30 EC and LVD directive 2014 35 EC In its condition upon delivery this device conforms to the conditions in the RoHS directive 2011 65 EU incl 2015 863 EU on the restriction...

Страница 8: ...eights Dimensions height x width x depth 112 x 355 x 220 mm Weight 4 7 kg Device type Name ZEISS Server Model 5034555 Interface front side Standby with LED status display 1 x RGB LED button Changeable...

Страница 9: ...grease before at taching the rubber pads Fig 2 Rubber pads must be attached on the right side of the server for installing the server upright Proceed as follows when starting up the ZEISS Server 1 Us...

Страница 10: ...pera tion ZEISS Server is ready to be operated Button is blue cyan flickering ZEISS Server is ready for opera tion with HDD access ZEISS Server is ready for op eration HDD is in use Button is red Temp...

Страница 11: ...Instructions for the ZEISS Server function 11 EN_20_012_0043l...

Страница 12: ...43 5577 89901 FN Nr 329733b Feldkirch ISO9001 ISO13485 www sie at Carl Zeiss Vision GmbH Turnstrasse 27 73430 Aalen Germany Phone 49 0 7361 598 5003 Fax 49 0 7361 591 475 E mail service vts global ze...