Key
Component
Qty
Tools & Material Required
A
Wall Plug
4
B
Bracket
4
C
Screw - Cross Head, 6mm dia x 60mm
4
D
Grub Screw
4
E
Allen Key
1
Screwdriver - crosshead
Pliers
Electric drill
Masonry drill bit
Spirit level
Stepladder (for taller radiators)
A
D
C
B
E
Assembly Instructions
Accurately mark out bracket holes on wall using spirit level.
Drill four holes to a minimum depth of 65mm & insert wall plugs (A).
Screw brackets (B) into wall plugs (A) with 6mm diameter x 60mm
screws (C).
Offer radiator up to wall and slide square posts on the rear of the
radiator into brackets (B).
Secure radiator in position by tightening grub screw (D) with Allen
key (E).
Electric radiators should be fitted only by a qualified electrician and
must be earthed and connected to a cable outlet in the bathroom
in accordance with I.E.E. wiring regulations. The electrical
connection should be made to a ‘5 amp fused fixed spur’ located
outside the bathroom.
Note: for maintenance purposes, cable outlets must remain
accessible and cables must not be buried directly into walls.