14 - EN
Values
Time delay
Sub-menu
Description
Minimum
Maximum
Factory
reset
P23
(Optional)
Note:
Only applies to systems fitted
with a corded 3-position
switch.
Deactivation delay for ventilation
setting 3.
■
If you BRIEFLY engage ventilation
setting 3 (<3sec.), the ComfoAir
switches to the HIGH SETTING
for “x” minutes and then switches
back automatically to the normal
ventilation setting.
If a 3-position switch is operated during
the time delay mode, then the ComfoAir
switches immediately to the selected
ventilation setting.
0 Min.
120 Min.
0 Min.
P24
Filter warning
■
“x” weeks after the filter has been
cleaned or replaced, a “filter dirty”
alert will appear once again.
10 weeks
26 weeks
16
weeks
P25
(Optional)
Note:
Only applies to systems fitted
with an RF switch.
Deactivation delay for ventilation setting
3 (using
).
■
After pressing
BRIEFLY (<2
sec.), the ComfoAir switches to the
high setting for “x” minutes and then
switches back automatically to the
normal ventilation setting.
If a 3-position switch is operated during
the time delay mode, then the ComfoAir
switches immediately to the selected
ventilation setting.
1 Min.
20 Min.
10 Min.
P26
(Optional)
Note:
Only applies to systems fitted
with an RF switch.
Deactivation delay for ventilation setting
3
.
■
After pressing and HOLDING (>2
sec.)
, the ComfoAir switches to the
high
setting for “x” minutes and
then switches back automatically to the
normal ventilation setting.
If a 3-position switch is operated during
the time delay mode, then the ComfoAir
switches immediately to the selected
ventilation setting.
1 Min.
120 Min.
30 Min.