3.1.4

 

Smart Summer Bypass Manual Override

 

  

To manually override the Smart Summer Bypass Mode:

Press control button to activate panel 

Scroll to “User Menu” option and press button to enter 

Scroll to “Summer Bypass" option and press button

The current setting status will flash

Rotate button to desired outcome

Press to confirm

Screen will time out after 30 seconds

Note:

  

If "manual" option selected, the option will be available to 

"OPEN" or "SHUT" the summer bypass

Rotate button to desired outcome and press to confirm

Rotate button to select period of time required

Press to confirm

   

Factory set to AUTO 

     Options  AUTO / MAN

  

Note: 

 

          

   

Unit  will  return  to  “Auto  Mode”  at  the  end  of  the  manual  time  out  period.   

 

                                               

   

Unit will not allow the Summer ByPass to be opened at temperature below 7

o

C.

 

3.1.5

 

Ventilation Speed Control for ZGS2

 

  

The ZGS2 is a hard wired switch used to switch between Low and High speed

Press the switch towards the (I) to activate the Low Speed 

Press the switch towards the (II) to activate the High Speed

S U M M E R

B Y P A S S

< M A N . >

6

Содержание ComfoAir Compact CA155WM

Страница 1: ...ComfoAir Compact CA155WM CA155CM CA185WM Mechanical Ventilation with Heat Recovery User Homeowner Guide CA155WM CA155CM CA185WM...

Страница 2: ...Contents 2 User Homeowner Information Page 1 0 Ventilation In Your Home 3 2 0 General Overview 3 3 0 Controls 4 4 0 Servicing and Maintenance 7 5 0 Guarantee 16...

Страница 3: ...ing manually using our ZGS2 switch or via switch live ZGS2 switch markings Low I High II operation Note Other manufacturers switches may show different markings or your unit may be connected to a Buil...

Страница 4: ...providing you with information and cannot be changed O U T D O O R T E M P o C 7 B O W L E Example 3 Warning Alert Message Warning message always indicated by flashing text and exclamation marks Pleas...

Страница 5: ...home from overheating See 3 1 4 for adjust function setting Auto Manual Frost Protection Frost protection monitors the internal and external temperature and automatically identifies when the frost pro...

Страница 6: ...lable to OPEN or SHUT the summer bypass Rotate button to desired outcome and press to confirm Rotate button to select period of time required Press to confirm Factory set to AUTO Options AUTO MAN Note...

Страница 7: ...or cleaning replacement of the heat exchanger should be carried out The filters should help to protect the heat exchanger but over time dirt in the atmosphere can penetrate the filters and gain acces...

Страница 8: ...n and press button to enter First option is the Service Log which indicates the number of logs for review Scroll to H Exch Change option and press button The request to reset timer will flash Press to...

Страница 9: ...ont panels in the bottom tabs u and click them back into place at the top v Turn the Mains Supply back on Reset Filter Status See Section 4 1 4 4 1 9 To replace the ComfoAir CA155CM Filters Replace at...

Страница 10: ...at approximately 1 year intervals HR185WM FILTER step1 2 1 HR185WM FILTER step2 Step 1 Isolate ComfoAir CA185WM from the Mains Supply Pull down the top part of the two front panels u and lift out v of...

Страница 11: ...Remove the heat exchanger by gently pulling on the nylon strap taking care not to damage it Clean each face of the heat exchanger with a vacuum cleaner and wash with warm water Ensure heat exchanger...

Страница 12: ...3 HR155CM heatexchanger step4 Step 3 Supporting with your hand gently remove the heat exchanger taking care not to tilt it to an angle as water will be present Clean each face of the heat exchanger wi...

Страница 13: ...of locating tabs at the bottom and remove valance w HR185WM heatexchanger step4 Step 3 Unscrew the six heat exchanger locating screws and remove panel Step 4 Remove the heat exchanger by gently pulli...

Страница 14: ...ttom tabs v and secure in place with two screws w Step 8 Locate the front panels in the bottom tabs u and click them back into place at the top v Turn the Mains Supply back on Reset Heat Exchanger Sta...

Страница 15: ...Access for Maintenance 4 2 5 Footprint of ComfoAir CA155WM 500mm HR155WM Top View 4 2 6 Footprint of ComfoAir CA155CM 500mm HR155CM Side View 4 2 7 Footprint of ComfoAir CA185WM 600mm HR185WM Top Vie...

Страница 16: ...Year Guarantee 5 1 1 This does not affect your statutory rights 5 1 2 Full details available on request All information is believed correct at time of going to press E OE All goods are sold according...

Отзывы: