background image

Zehnder EDT2

2

Z-CALADAIR-V1122-CSY-INM-EDT2

Safety and environmental guidelines

In accordance with the regulations in force, the installation of the equipment must only be carried out by technically 

qualified personnel authorised for this type of appliance and work. 

Do not use the appliance for any purpose other than that for which it is designed. This appliance can only be used in 

combination with the CLD-283 electronic controller which is part of the EASY 5.0 system.

Before any intervention, make sure that the appliance connected to the Zehnder EDT2 Wall-Mounted Touchscreen User 

Controller is de-energised and wait for the moving parts of the ventilation unit to come to a complete stop before 

opening the doors, panels and access hatches.

The appliance can only be switched on and off via the proximity switch.

The safety and control equipment of the appliance connected to the Zehnder EDT2 Wall-Mounted Touchscreen User 

Controller must not be removed, short-circuited or disabled.

All waste produced must be handled in accordance with the regulations in force.

We accept no liability for damage resulting from misuse of the equipment, unauthorised repair or modification or failure 

to observe these instructions.

Reminder and definition of the pictograms used

Danger and warning :
- Operation or situation that may be hazardous
- Warning that there are instructions to be observed

Reading the documentation that accompanies the product is mandatory.

Содержание CALADAIR EDT2

Страница 1: ...Designer radiator Controlled indoor ventilation Radiant ceiling heating and cooling Clean air solutions Installation Service and User Manual Zehnder EDT2 always the best climate...

Страница 2: ...or the moving parts of the ventilation unit to come to a complete stop before opening the doors panels and access hatches The appliance can only be switched on and off via the proximity switch The saf...

Страница 3: ...force No packaging should be released into the environment Supply voltage 24 V AC DC Consumption 60mA Protection class IP30 Ambient humidity 10 90 without condensation Indoor temperature 0 50 C operat...

Страница 4: ...ion manually It must be reactivated when the programmed time has elapsed Putting the display on standby Press and release Information display Current ventilation mode Ventilation running in reduced mo...

Страница 5: ...the Zehnder EDT2 Wall Mounted Touchscreen User Controller according to the wiring diagram see VII ELECTRICAL CONNECTION 7 Fit the Zehnder EDT2 Wall Mounted Touchscreen User Controller onto the support...

Страница 6: ...of the controller Connect the power leads to terminals 24 and N Ventilation unit side Connect the power leads to terminals 7 and 8 taking into account the polarity Connect the data wires twisted pair...

Страница 7: ...Touchscreen User Controller 24 V DC between terminals 24 and N of the Zehnder EDT2 The screen displays OFFL There is no communication Check that communication is enabled in the CLD 283 controller Che...

Страница 8: ...IR V1122 CSY INM EDT2 en Zehnder Caladair reserves the right to change its production without notice Zehnder Caladair International 61 Rue Saint V ran 71000 M con France caladair caladair com www cala...

Отзывы: