background image

Zebra-Tech Ltd

  

 

D-OptoLogger Operation Manual

 

 

8

 

 

Figure 5:

 Pressure Correction Calculator 

Содержание D-Opto

Страница 1: ...D Opto Logger Dissolved Oxygen Logger Operation Manual...

Страница 2: ...9 3 1 Installation 9 3 2 Sealing the D Opto Logger 9 3 3 Logging Endurance 9 3 4 Routine Maintenance 10 3 5 Calibration 11 Appendix 1 Data File Format 13 Appendix 2 Communication Cable Wiring Scheme 1...

Страница 3: ...lved oxygen The basic principle involves subjecting a fluorescing compound ruthenium to a fixed wavelength of light When the light source is removed the compound emits a fluorescence the intensity of...

Страница 4: ...on of the D OptoLog software During installation the user can select the working path and directory however it is recommended that the default is used c Program Files D OptoLog 2 2 Operation The D Opt...

Страница 5: ...the computer s USB port via a USB to serial converter the port number will probably be either com port 4 or 5 The selected com port is maintained in an configuration file on the PC Once the correct p...

Страница 6: ...the desired logging parameters The Plot button enables a graphical plot of historic D Opto Logger data to be displayed on the screen The Calibration button opens the D Opto Logger Calibration window F...

Страница 7: ...nt of fully aerated water Figure 5 It will accept either altitude m or barometric pressure mBar By pressing the Restore defaults button the original factory calibration values are reinstated by the D...

Страница 8: ...Zebra Tech Ltd D OptoLogger Operation Manual 8 Figure 5 Pressure Correction Calculator...

Страница 9: ...ced prior underwater deployment 1 Using the O ring pick supplied remove the O rings from the inside of the end cap and the body of the D Opto Logger 2 Using a lint free tissue clean the O ring seats t...

Страница 10: ...to allow a sufficient period of time for temperature equilibration to occur 2 Place the D Opto Logger in a solution of known dissolved oxygen content A solution of 0 dissolved oxygen saturation can be...

Страница 11: ...1 Place the D Opto Logger in the reference solution and allow equilibrating for at least 30 minutes 2 Power up the D Opto Logger and start D OptoLog Once the measurements have stabilised press the Cal...

Страница 12: ...minutes 2 Power up the D Opto Logger and start D OptoLog Once the measurements have stabilised press the Calibrate button in the main window to open the Calibration window 3 Enter the pressure correct...

Страница 13: ...ptoLogger Operation Manual 13 Appendix 1 Data File Format Data Field Number Description 1 Year 2 Month 3 Day 4 Hour 5 Minute 6 Second 7 Battery voltage 8 Temperature Degrees C 9 Dissolved Oxygen 10 Di...

Страница 14: ...Zebra Tech Ltd D OptoLogger Operation Manual 14 Appendix 2 Communication Cable Wiring Scheme...

Страница 15: ...battery and communication socket there is an LED The LED flashes according to the current status of the D OptoLogger The interval between the flashing sequence may be up to 8 seconds 1 Flash Operation...

Страница 16: ...e instrument has been carefully designed to prevent electrical interference impacting on the operation Under extreme conditions however noise may become a problem Track down the source of noise this c...

Страница 17: ...ter Resolution Temperature 00 01 Deg C DO saturation 000 01 PPM 00 001 ppm Sensor Drift 1 per year provided measurement interval 10 minutes Power supply 1 x PP9 9 volt alkaline battery Duracell or Ene...

Страница 18: ...1 983 97 343 1126 973 96 431 1413 963 95 519 1703 952 94 608 1995 942 93 698 2290 932 92 789 2587 922 91 880 2887 912 90 972 3190 902 89 1066 3496 899 88 1160 3804 882 87 1254 4115 871 86 1350 4430 86...

Страница 19: ...Ltd D OptoLogger Operation Manual 19 Appendix 7 Useful Conversions Convert from To Calculation kPA mBar Multiply by 10 inHg mBar Multiply by 33 85 Feet Meters Multiply by 0 3048 Centigrade Fahrenheit...

Страница 20: ...Zebra Tech Ltd D OptoLogger Operation Manual 20 Zebra Tech Ltd Contact Details PO Box 1668 Nelson New Zealand Tel 0064 03 5471590 Fax 0064 03 5471598 Email enquiry zebra tech co nz...

Отзывы: