Barcode 

Value 

Barcode Label 

Description 

CB13 

No check character 

CB14 

Validate modulo 16,but don’t transmit 

CB15 

Validate modulo 16 and transmit 

DC50 

Codabar data redundant check=off 

DC51 

Codabar data redundant check=1 

DC52 

Codabar data redundant check=2 

DC53 

Codabar data redundant check=3 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

End Of Configuration 

Содержание Z-325x

Страница 1: ...Z 325XBT GLLS 1...

Страница 2: ......

Страница 3: ...y Changes to the original manual are listed below Version Date Description of Version 1 0 2014 01 22 Initial release 1 1 2014 04 21 Added Windows connection instructions 1 2 2014 07 09 Added SSP mode...

Страница 4: ...iological manual or otherwise except for brief passages which may be quoted for purposes of scholastic or literary review without express written consent and authorization We reserve the right to make...

Страница 5: ...manufacturer and authorized dealer or experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commission help...

Страница 6: ...microscopes but do not include normal eye glasses worn by the user CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiat...

Страница 7: ...er wireless devices in the following locations as it may cause an accident Where inflammable gas is present in a hospital train airplane or a petrol station Near automatic doors or a fire alarm This u...

Страница 8: ...se this frequency If you use these wireless devices in your office your device might not be able to hear the signals over the noise coming from them If your network uses wireless G you can quiet the n...

Страница 9: ...Type 7 Dongle Host Mode 7 SPP Master SPP Slave Mode 7 HID Mode 7 Scanner USB online to Host 8 USB Online Mode 8 Visible Indicators 8 Scanner LED 8 Dongle LED 9 Sound Indicators 9 ACK NAK Protocol or F...

Страница 10: ...P Master Slave mode 38 Device Setting 38 Data Transmit Mode 40 Radio protocol communication parameter 41 Power off timeout parameter 42 Same Code Delay 43 Operation Function Setting 45 Good Read Beepe...

Страница 11: ...ter Setting 63 Industrial 2 of 5 Parameter Setting 64 UPC EAN JAN Parameter Setting 65 Telepen Parameter Setting 70 Matrix 2 of 5 Parameter Setting 71 Data Editing 75 Identifier Code 75 Header and Tra...

Страница 12: ......

Страница 13: ...ations The scanner includes a 32 bit CPU and excellent scan engine in a small yet powerful unit delivering intuitive and rapid scanning regardless of environment Key Features Compact light weight and...

Страница 14: ...ies The scanner package contains Wireless scanner with battery Dongle optional Micro USB to USB cable 5V USB Power adapter Quick Guide If any contents are damaged or missing please contact your dealer...

Страница 15: ...ovided by the manufacturer to avoid any non compatible danger or void the warranty 1 Move the lock for the battery compartment to the unlock position and remove the back cover 2 Align the metal contac...

Страница 16: ...ctor to the host to begin charging You can also connect the USB cable to an outlet using the power adapter to charge the battery 3 The battery begins charging when the scanner LED indicator starts fla...

Страница 17: ...ep sound is heard to turn on the scanner 3 To power off the scanner press and hold the function off button for 3 second until 2 short beeps are heard Power on Power off Function Button The function bu...

Страница 18: ...1 Power on the scanner 2 Press the scan trigger and aim at the barcode 3 When decoding is successful the scanner beeps and the LED indicates blue Presentation Scanning 1 Set the scanner for presentat...

Страница 19: ...ivery box are paired in factory As soon as both are powered on they should find and connect to each other immediately However under special circumstance that the scanner and the dongle are not paired...

Страница 20: ...ata Visible Indicators Scanner LED Please see the following for the operational indication of the scanner LED Status Indication Blue flashing Waiting for radio connection flash time 0 5s 0 5s Blue fas...

Страница 21: ...te mode Sound Indicators When the scanner is in operation it provides audible feedback The beeps indicate the status of the scanner Beep Indication A long beep Power on scanner One beep A barcode has...

Страница 22: ...dy Wireless Scanner 10 ACK NAK Protocol or Frame Packing When scanner is in SPP Master Slave mode and add in the data protocol or packing could confirm the data reliability Refer to below for differen...

Страница 23: ...data length excluding header character Format Byte FEH Differentiate data format barcode data is always FEH Data ID The number of each data If receive the same ID more than once only the first one is...

Страница 24: ...x05 MSI 0x07 Firmware Update To update the firmware scan the Start of Configuration barcode then scan Dongle USB Update or Scanner USB Update to enter Firmware Update mode To exit Firmware Update mode...

Страница 25: ...ation Power off and on the scanner when the setting is done 5 To give up a configuration change power off the scanner before scanning the End of Configuration barcode or scan the Abort barcode 6 For s...

Страница 26: ...Parameter Default Radio communication Wireless host Dongle Pairing mode Unlocked Data transmit Normal Radio protocol timeout 5 seconds Power off timeout 20 minutes Encryption Enable Dongle Host RS 23...

Страница 27: ...EX standard Disable Identifier code as AIM standard Disable Code 39 identifier code M ITF 2 of 5 identifier code I Chinese post code identifier code H UPC A identifier code A UPC E identifier code E E...

Страница 28: ...13 EAN 8 D1 D2 D3 D4 D5 D6 D7 D8 UPCA D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 UPCE D1 D2 D3 D4 D5 D6 D7 D8 CODE128 D1 Dx default 3 62 EAN128 C1 D1 Dx default 3 62 CODE39 D1 Dx default 3 62 CODABAR D1 D...

Страница 29: ...and transmit data You may enable or disable the functions using the following settings Disable USB communication USB online scan disable Disable USB communication Enable USB communication USB online...

Страница 30: ...host If the LED shows steady blue the scanner is already paired to another scanner so you must unpair the scanner before continuing 2 Power on the scanner and enable dongle host mode if necessary Dong...

Страница 31: ...ions To connect a wireless device to Window based system for the first time 1 Turn on the host computer and activate its wireless connection 2 Select Add Bluetooth device Or open the dialog Bluetooth...

Страница 32: ...rst time 1 Turn on the host computer and activate its wireless connection 2 Select Add wireless device Or open the dialog BT devices and click Add 3 Power on the scanner and program it with Scanner SP...

Страница 33: ...less Scanner 21 5 Select Outgoing computer initiate the connection and then click Browse 6 The scanner should be on the list of discoverable devices The default name of the scanner is Z 325X BT Select...

Страница 34: ...USER S MANUAL Handy Wireless Scanner 22 7 Write down the COM port number for later use 8 Select the Device tab to go back to the device page...

Страница 35: ...luetooth Device Wizard and click Next The default pin code is 12345678 11 13 Click Ok when the connection is established 12 Open HyperTerminal or other serial port programs and select the COM port you...

Страница 36: ...t time 1 Turn on the host computer and activate its wireless connection 2 Select Add wireless device Or open the dialog BT devices and click Add 3 Power on the scanner and program it with Scanner SPP...

Страница 37: ...USER S MANUAL Handy Wireless Scanner 25 5 Select Incoming scanner initiate the connection and then click OK 6 Write down the COM port number for later use...

Страница 38: ...ogramming Guide to input the 12 digit device address For example if the address is 011B1345600 scan 0 0 1 1 B 1 3 4 5 6 0 0 from ASCII barcode labels 11 Scan Confirm Setting to store the address Confi...

Страница 39: ...luetooth Device Wizard and click Next The default pin code is 12345678 16 13 Click Ok when the connection is established 17 Open HyperTerminal or other serial port programs and select the COM port you...

Страница 40: ...e Enable wireless HID keyboard emulation Smart phone mode For smart phone mode HID MODE must also be enabled 2 Enable wireless connection on your host and follow the instructions in your host to set i...

Страница 41: ...store the pin code Set pin code Set pin code SPP Master only Confirm Setting for address and pin code setting required Please check the User s Manual from your PC for device address and pin code Dele...

Страница 42: ...e to input the name Max 12 digits 3 Scan Confirm Setting to store the new name Friendly device name set Change the display name when scanner is discovered Confirm Setting for address and pin code sett...

Страница 43: ...cts to the host via SPP Slave SPP Master HID HID Keyboard or HID Multi Media Keyboard mode without pin code when the host supports it For Apple or Android Mode Enable Apple or Android mode SSP Enable...

Страница 44: ...the scanned data will be transferred to the host computer immediately If the scanner is out of its connecting range the scanner does not send or store any data Data transmit normal Batch mode is disab...

Страница 45: ...code 2 Batch mode Note Scanner LED indicator will not flash while waiting for connection in this mode Clearing Batch Use the settings in this section to clear the stored data Clear batch data after se...

Страница 46: ...tion Press and hold the trigger for over 1 second to send the data Batch Mode Sounds Settings Use the settings in this section to setup the sound Out of range resend data with beeper sound Add beeper...

Страница 47: ...Return scanner to factory defaults Return dongle host to factory defaults Return to USB default Communication dongle link required Return as USB virtual COM port default Communication dongle link requ...

Страница 48: ...ode The scanner is still active after the data is transmitted but the successive transmission of the same barcode is not allowed when the trigger switch is pressed again Alternate mode The scanner ill...

Страница 49: ...tup Unlock pairing mode In this mode the scanner can pair with another dongle when disconnected Lock pairing mode In this mode the scanner can not pair with another dongle Undo pairing Undo the pairin...

Страница 50: ...xxxT in CODE39 format Scanner SPP Slave enable Setting wireless address SPP Master only Set PIN code SPP Master only Device Setting Show device address after friendly name enabled Enable showing devic...

Страница 51: ...code Confirm Setting for address device name and pin code setting required Required Pair with slave SPP Master Discover enable Discover disable Encryption enable Encryption disable Data communication...

Страница 52: ...ata By Scanning Label Clear batch data after send Clear batch data by scanning Delete batch data label Delete batch data Send Batch Data on line USB cable contact Send Batch data on dongle Out of rang...

Страница 53: ...dio protocol communication parameter Radio protocol timeout 3 sec Radio protocol timeout 5 sec Radio protocol timeout 8 sec Radio protocol timeout 10 sec Radio protocol timeout 13 sec Radio protocol t...

Страница 54: ...Power off timeout parameter Power off timeout 5 min Power off timeout 10 min Power off timeout 20 min Power off timeout 30 min Power off timeout 1 hr Power Off timeout 2 hr Power Off timeout 4 hr Powe...

Страница 55: ...r 43 Start Of Configuration Power Always On Power off by scanning this label Link beeper enable Link beeper disable Power up beeper enable Power up beeper disable Same Code Delay 50 msec 100 msec 200...

Страница 56: ...USER S MANUAL Handy Wireless Scanner 44 Start Of Configuration 400 msec 500 msec 600 msec 700 msec 800 msec 1000 msec Infinite End Of Configuration...

Страница 57: ...S MANUAL Handy Wireless Scanner 45 Start Of Configuration Operation Function Setting Good Read Beeper Tone Selection Medium beeper tone High beeper tone Low beeper tone Speaker disable End Of Configur...

Страница 58: ...USER S MANUAL Handy Wireless Scanner 46 Start Of Configuration Beeper duration Selection Long Medium Short Ultra Short Ultra Long End Of Configuration...

Страница 59: ...USER S MANUAL Handy Wireless Scanner 47 Start Of Configuration Inter Character Delay 0 ms 2 ms 5 ms 10 ms 20 ms 50 ms Inter Message Delay 0 ms 100 ms 500 ms 1000 ms End Of Configuration...

Страница 60: ...rface Setting Start Of Configuration Message Terminator RS 232 message terminator none RS 232 message terminator CR LF RS 232 message terminator CR RS 232 message terminator LF RS 232 message terminat...

Страница 61: ...oard language support FRENCH send scan code Keyboard language support SPANISH send scan code Keyboard language support ITALIAN send scan code Keyboard language support Switzerland send scan code Keybo...

Страница 62: ...USER S MANUAL Handy Wireless Scanner 50 Start Of Configuration Message Terminator Keyboard terminator none Keyboard terminator Enter Keyboard terminator H TAB End Of Configuration...

Страница 63: ...le or disable Software keypad To enable disable Software keyboard 1 Scan the Start Of Configuration barcode 2 Scan the Multi media keyboard mode barcode 3 Scan the End Of Configuration barcode 4 Conne...

Страница 64: ...ar start stop character transmission none CB06 Codabar start stop character transmission A B C D CB07 Codabar start stop character transmission DC1 DC4 CB08 Codabar start stop character transmission a...

Страница 65: ...bel Description CB13 No check character CB14 Validate modulo 16 but don t transmit CB15 Validate modulo 16 and transmit DC50 Codabar data redundant check off DC51 Codabar data redundant check 1 DC52 C...

Страница 66: ...isable RC13 Code 32 enable RD13 Code 32 disable DC00 Code 39 data redundant check off DC01 Code 39 data redundant check 1 DC02 Code 39 data redundant check 2 DC03 Code 39 data redundant check 3 3901 S...

Страница 67: ...9 check digit calculate but without transmit 3907 No check character 3908 Code 39 maximum length setting 3909 Code 39 minimum length setting SET Confirm to save this setting required for reading full...

Страница 68: ...dant check 1 DC32 Code 93 data redundant check 2 DC33 Code 93 data redundant check 3 9301 Code 93 maximum length setting 9302 Code 93 minimum length setting SET Confirm to save this setting required f...

Страница 69: ...40 Code 128 data redundant check off DC41 Code 128 data redundant check 1 DC42 Code 128 data redundant check 2 DC43 Code 128 data redundant check 3 1803 No check character 1804 Calculate but not trans...

Страница 70: ...sable DC60 Chinese post code data redundant check off DC61 Chinese post code data redundant check 1 DC62 Chinese post code data redundant check 2 DC63 Chinese post code data redundant check 3 SZ01 Chi...

Страница 71: ...2 MSI Plessy minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting MS03 MSI Plessy double check digit calculate but not transmit MS04 MSI Ple...

Страница 72: ...ode 11 minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting 1103 Code 11 one check digit verification 1104 Code 11 two check digit verificat...

Страница 73: ...F 2 of 5 disable RC09 IATA code enable RD09 IATA disable DC80 ITF 25 data redundant check off DC81 ITF25 data redundant check 1 DC82 ITF25 data redundant check 2 DC83 ITF25 data redundant check 3 IT03...

Страница 74: ...ITF 2 of 5 code maximum length setting IT02 ITF 2 of 5 code minimum length setting IT06 ITF 2 of 5 one fixed length setting IT07 ITF 2 of 5 two fixed length setting SET Confirm to save this setting re...

Страница 75: ...e disable D051 Standard 2 of 5 code maximum length setting D052 Standard 2 of 5 code minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting D0...

Страница 76: ...sable D251 Industrial 2 of 5 code maximum length setting D252 Industrial 2 of 5 code minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting D2...

Страница 77: ...rt to ISSN ISBN enable RD11 EAN convert to ISSN ISBN disable RC03 UPC EAN JAN enable RD03 UPC EAN JAN disable UE01 UPC EAN JAN all enable UE02 EAN 8 or EAN 13 enable UE03 UPC A and EAN 13 enable UE04...

Страница 78: ...le UE15 Force UPC A to EAN 13 format enable UE16 Force UPC A to EAN 13 format disable UE44 Force EAN 8 to EAN 13 format enable UE45 Force EAN 8 to EAN 13 format disable UE17 Transmit UPC A check digit...

Страница 79: ...able UE27 Transmit UPC A leading character enable UE28 Transmit UPC A leading character disable UE30 Add on format with separator UE31 Add on format without separator UE60 EAN 13 country code first 0...

Страница 80: ...k 1 DC16 UPC E data redundant check 2 DC17 UPC E data redundant check 3 DC20 EAN 13 data redundant check off DC21 EAN 13 data redundant check 1 DC22 EAN 13 data redundant check 2 DC23 EAN 13 data redu...

Страница 81: ...irement not sent for other UE38 EAN UPC addon mandatory for 978 977 bookland Supplement requirement optional for other UE42 EAN UPC addon mandatory for 491 Japanese bookland Supplement requirement not...

Страница 82: ...less Scanner 70 Start Of Configuration Telepen Parameter Setting Barcode Value Barcode Label Description RC25 Telepen enable RD25 Telepen disable TE03 Telepen numeric mode enable TE04 AIM Telepen enab...

Страница 83: ...ix 2 of 5 disable D151 Matrix 2 of 5 maximum length setting D152 Matrix 2 of 5 minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting D153 Mat...

Страница 84: ...ly RSS Limited GS1 DataBar Limited Group 3 GS1 DataBar Expanded Formally RSS Expanded GS1 DataBar Expanded GS1 DataBar Expanded Stacked GS1 DataBar Omnidirectional Formally RSS 14 Barcode Value Barcod...

Страница 85: ...Barcode Label Description RC16 GS1 DataBar Limited enable RD16 GS1 DataBar Limited disable SS10 Transmit GS1 DataBar Limited check digit SS11 Don t transmit GS1 DataBar Limited check digit SS12 Transm...

Страница 86: ...enable RD17 GS1 DataBar Expanded disable SS07 GS1 DataBar Expanded EAN 128 emulation enable SS06 GS1 DataBar Expanded EAN 128 emulation disable SS08 GS1 DataBar Expanded check digital enable SS09 GS1...

Страница 87: ...Enable identifier code table as AIM standard CI01 Code 39 identifier code setting CI02 ITF 2 of 5 identifier code setting CI03 Chinese Post Code identifier code setting CI04 UPC E identifier code sett...

Страница 88: ...ting CI12 GS1 DataBar Omnidirectional identifier code setting CI13 GS1 DataBar Limited identifier code setting CI14 GS1 DataBar expanded identifier code setting CI15 Industrial 2 of 5 identifier code...

Страница 89: ...tion CP11 Add code length as header enable 2 digits CP12 Add code length as header disable 2 digits HT01 Header Preamble HT02 Trailer Postamble HT03 Truncate header character HT04 Truncate trailer cha...

Страница 90: ...SCII DC4 Function key F4 14 Full ASCII ACK Function key Down arrow 06 Full ASCII NAK Function key F5 15 Full ASCII BEL Function key Left arrow 07 Full ASCII SYN Function key F6 16 Full ASCII BS Functi...

Страница 91: ...L 1F Full ASCII 2E Full ASCII SP 20 Full ASCII 2F Full ASCII 21 Full ASCII 0 30 Full ASCII 22 Full ASCII 1 31 Full ASCII 23 Full ASCII 2 32 Full ASCII 24 Full ASCII 3 33 Full ASCII 25 Full ASCII 4 34...

Страница 92: ...E Full ASCII M 4D Full ASCII 3F Full ASCII N 4E Full ASCII 40 Full ASCII O 4F Full ASCII A 41 Full ASCII P 50 Full ASCII B 42 Full ASCII Q 51 Full ASCII C 43 Full ASCII R 52 Full ASCII D 44 Full ASCII...

Страница 93: ...5C Full ASCII k 6B Full ASCII 5D Full ASCII l 6C Full ASCII 5E Full ASCII m 6D Full ASCII _ 5F Full ASCII n 6E Full ASCII 60 Full ASCII o 6F Full ASCII a 61 Full ASCII p 70 Full ASCII b 62 Full ASCII...

Страница 94: ...t Of Configuration Full ASCII Code 39 Table continued Code 39 ASCII Hexa code Code 39 ASCII Hexa code Full ASCII x 78 Full ASCII 7C Full ASCII y 79 Full ASCII 7D Full ASCII z 7A Full ASCII 7E Full ASC...

Страница 95: ...USB virtual COM port 1 Connect the handheld scanner and the host e g a PC with a USB interface cable 2 Enable USB virtual COM port with programming barcode on page 32 3 After the programming the host...

Страница 96: ...ple If the barcode length is 4 to 12 digits the steps would be as below End Set up barcode length Start Set up minimum barcode length Start of Configuration Set up maximum barcode length End of Config...