1. Zeal guarantees that the infrared ear thermometer will 

be free from manufacturing defects under normal use for 

a period of two years from the date of purchase subject 

to the following terms and conditions .

2.This warranty covers normal use only. This warranty 

does not cover batteries or other power sources that may 

be provided with or used with the infrared ear thermometer. 

This warranty is voided if the infrared ear thermometer 

product is misused or abused in any manner.

3.This warranty does not cover the cost of round-trip 

transport for repair, the result of, or damage caused by 

improper use of thermometer and any other consequential 

loss or damage claims. 

WARRANTY

The Clinicians choice

ZEAL

THE GOLD STANDARD SINCE 1888

G.H. Zeal Limited

Zeal House

8 Deer Park Road

London SW19 3UU

England

Phone:  +44 (0) 20 8542 2283

Fax: 

+44 (0) 20 8543 7840

E-mail: [email protected]

Web: www.zeal.co.uk

ZEAL

THE GOLD STANDARD SINCE 1888

    THE QUALITY YOU CAN DEPEND ON FROM THE PEOPLE YOU TRUST

                             PARTNERS WITH THE NHS SINCE 1948

SUPPLIERS TO THE NHS SINCE 1948

NHS

Содержание ACT8000

Страница 1: ...PANIC THERMOMETER Innovation Quality and Service since 1888 ModelACT8000 Infrared Ear Thermometer Instructions for Use NHS NPC FWH153 MPC ACT8000 SUPPLIERS TO THE NHS SINCE 1948 NHS ZEAL THE GOLD STAN...

Страница 2: ...e cover attached clean the lens before next use see section on cleaning the product page 21 The thermometer contains small parts that can be swallowed or produce a choking hazard to children Always ke...

Страница 3: ...temperatures from the same ear and wait at least two minutes between assessments Repeatedly inserting a probe at room temperature into a patient s ear will cause the ear to cool down resulting in lowe...

Страница 4: ...or plugs remove the object 20 minutes prior to taking a temperature measurement Other factors may affect correct ear temperature measurements particularly when a patient has been lying on their side p...

Страница 5: ...LIGHT PROBE COVER EJECTOR BUTTON BATTERY COMPARTMENT COVER PROBE COVER SENSOR THE TYMPANICEARTHERMOMETERPARTS MODELACT8000 BATTERY CHARGING TERMINALS MODEL ACT8000R ONLY 8 9 STORAGECRADLEPARTS STORAG...

Страница 6: ...ver box The probe cover box should be pushed down gently but firmly over the dispenser arms until the arms penetrate into the inside base of the box In view of the special design of the probe cover bo...

Страница 7: ...obe cover press the EJECT button and put on a new clean cover Pleaseensurethattheusedprobecoversaredisposed ofsafelyandhygienically FITTINGTHEPROBECOVERSTO MODELACT8000 HOW TO USE YOUR THERMOMETER 1 A...

Страница 8: ...0 The thermometer automatically stores the last 10 measurements taken into its memory The latest temperature taken is displayed first when recalled from the memory To recall a temperature from the mem...

Страница 9: ...by mistake the thermometer is placed in the ear canal without a probe cover in place the lens should be cleaned immediately To clean the probe lens gently wipe its surface with a cotton swab slightly...

Страница 10: ...Range 26 0 C to 43 9 C 78 F to 111 9 F Measurement Time 1 second approx Accuracy 0 2 C 0 4 F 35 5 C to 42 C 95 9 F to 107 6 F for ambient temperature 16 C to 40 C 0 3 C outside of this temperature ran...

Страница 11: ...ective 93 42 EEC This product complies with international electrical safety rating IP22 with regard to ingress of dust other foreign objects and water as required by IEC 60601 1 11 Caution consult acc...

Страница 12: ...HAT PROJECTS THE TEMPERATURE ONTO THE FOREHEAD OR EYELID HAS VISUAL CORRECT MEASURING DISTANCE TECHNOLOGY AND ROOM TEMPERATURE STABILISATION THE MOST PROFESSIONAL NO CONTACT THERMOMETER AVAILABLE CE F...

Страница 13: ...ed ear thermometer product is misused or abused in any manner 3 This warranty does not cover the cost of round trip transport for repair the result of or damage caused by improper use of thermometer a...