Max inverter power
Serial number of the machine
Software version installed
Hardware version
Inverter Info (1)
Serial
number:
ZM2ES060MBG265
Hardware version:
Software version:
V001
Press enter to view!
Safety firmware version:
V02000
Information on DRMs0 mode
(enable only for Australia)
Inverter Info (4)
Logic interface:
Disabled
Inverter Info (2)
Country:
001-000
Country code for the standard
Battery model set
Total battery capacity in Ah
Battery discharge percentage
Maximum charge current in A
Max voltage value (protection)
Max voltage value (charge)
Maximum discharge current in A
Min voltage value (discharge)
15.2 CHECKING OF BATTERY SETTINGS
15.1 CHECKING OF INVERTER SETTINGS
To check whether the parameters set are correct, enter the display menu under “Inverter Info” and check the
data, especially those highlighted:
Power level:
6 kW
Service Code Version
*Note
: if there is more than one battery, the sum
of the total capacities will be shown on the display
To CHECK whether the parameters set are correct, enter the display menu under “Battery Info” and check the
data, especially those highlighted
Measured value of the
insulation resistance
Inverter Info (5)
Insulation resistance:
7000KOhm
EPS safety value
Pylontech
WeCo 4K4 / 4K4LT / 4K4PRO
WeCo 5K3 / 5K3XP
Azzurro ZSX5000 / 5000 PRO / 5120
Battery-Info (1)
Battery type:
Pylon
Battery capacity:
Depth of Discharge
50 Ah
80%
BMS: 25.00A SET : 65.00A
Max charge curr. (A)
Battery-Info (2)
Overvoltage threshold:
54.0V
Max. charge threshold:
53.2V
Max. discharge curr.:
Min. discharge voltage:
47.0V
BMS: 25.00A SET : 65.00A
80% (EPS)
Battery-Info (1)
86 Ah
90%
BMS: 65.00A SET : 65.00A
Battery-Info (2)
59.3V
58.4V
48.0V
BMS: 65.00A SET : 65.00A
80% (EPS)
WeCoHeSU V0. 3. 54
Battery-Info (1)
100 Ah
90%
BMS: 65.00A SET : 65.00A
Battery-Info (2)
59.3V
58.4V
48.0V
BMS :65.00A SET : 65.00A
80% (EPS)
WECO628
Battery-Info (1)
100 Ah
90%
BMS: 50.00A SET : 65.00A
Battery-Info (2)
59.3V
58.4V
48.0V
BMS :50.00A SET : 65.00A
80% (EPS)
AZZURRO LVZSX5000
Battery type:
Battery capacity:
Depth of Discharge
Max charge curr. (A)
Overvoltage threshold:
Max. charge threshold:
Max. discharge curr.:
Min. discharge voltage:
Battery type:
Battery capacity:
Depth of Discharge
Max charge curr. (A)
Overvoltage threshold:
Max. charge threshold:
Max. discharge curr.:
Min. discharge voltage:
Battery type:
Battery capacity:
Depth of Discharge
Max charge curr. (A)
Overvoltage threshold:
Max. charge threshold:
Max. discharge curr.:
Min. discharge voltage:
Battery-Info (3)
EPS Safety Buffer:
20%
Battery-Info (3)
20%
Battery-Info (3)
20%
Battery-Info (3)
20%
EPS Safety Buffer:
EPS Safety Buffer:
EPS Safety Buffer:
Photovoltaic input mode
(Independent / Parallel)
Inverter Info (3)
PV Input Mode :
Working mode :
Independent
Automatic mode
Information on operating mode
(must be automatic)
RS485 address :
01
Communication address
(value must be different from 00)
EPS :
Disabled
Information on EPS mode
IV Curve Scan :
Disabled
Information on maximum grid
in-feed mode
Zero grid feed-in mode :
Disabled
Information on MPPT scan
mode
Power factor value
Power Factor :
1.00