SP230/SP230-S5
2x2 PtP/PtMP 802.11ac Wave 2 Outdoor Access Point
QSG
4
Grounding Connection & Protect from Lightning
1.
Make your device GND port connect to ground wire.
2.
The ground wire connects to the earth. In addition, the
grounding wire meets to 6-AWG copper grounding wire.
Safety Notice
1.
Do not install the device close to any electrical grounding device or lightning protection system.
Place the device’s own grounding and lightning protection system apart from any electrical
grounding device and lightning protection system as far as possible.
2.
Protect components from electrostatic discharge: Please wear an ESD wrist strap or handle the
power adapter by its edge and do not touch any component or printed circuit boards,
especially for module device.
3.
Make sure to keep the temperature and humidity of the installation location at an optimal
level.
4.
An excellent grounding system guarantees the stable operation of device, as well as to protect
device from lightning, interference and electrostatic discharges.
5.
If installed outdoors, the device may be damaged by lightning. We recommend that you install
additional lightning protection devices if necessary, considering the conditions in your area.
6.
Supply stable power to the device. Unstable power may cause the device to malfunction. The
device supports PoE power supply and is recommended if the device is installed near grid lines
within less than 100 meters radius.
Installing a Waterproof Cable Gland for Ethernet Port
(Optional accessory_
SP-WP-CM20)
Dismantle all the components of waterproof cable gland, and plug the cable
through it. Thread and assemble one by one: (1) sealing nut (2) plastic ring (3)
rubber (4) locking nut. Securely tighten all the components.
Note:
Be sure that grounding is available and that it
must comply with local and national electrical codes.
For additional lightning protection, use lightning rods
and lightning arrestors.