![Zaxcom ZMT4 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/zaxcom/zmt4/zmt4_user-manual_3224746010.webp)
Zaxcom ZMT4 Time Code Menu
10
TIME CODE MENU
Time Code Frame Rate Set
The time code frame rate menu is where the time code frame rate is set.
The ZMT4 will lock to and record all standard time code frame rates.
•
23.98, 24, 25, 29.97DF, 29.97DF, 30 DF, 30 NDF
Time Code Source Select
The time code source menu selects how the transmitter will receive its time code.
•
ZAXNET (RF)
- The ZMT4 will receive time code via ZaxNet
•
AUDIO INPUT
- The ZMT4, with a proper cable, will receive time code via the microphone input.
When time code is connected, it takes the transmitter approximately three seconds to recognize the TC.
The screen will display TIME CODE followed by JAM when it is recognized. Please note that when using the
microphone input connector, the audio level of the time code signal needs to be between -30 and -10 dBFS
on the unit’s meter. Any level above -10 may cause clipping, which will prevent proper reading of time
code.
TC Jam Mode Select
This menu controls if the ZMT4 will go into record when it receives a record run time code.
•
AUTO-JAM NORMAL
- The ZMT4 will continuously jam time code via ZaxNet and will go into record when
receiving a record command via ZaxNet or if the unit is put into record manually by pressing the CARD and
INC keys simultaneously.
•
AUTO-LOAD REC RUN
- In Auto-Load mode the ZMT4 will go into record when it detects rolling time code
and will stop when the time code stops. If time code is lost because the IFB signal is too weak the unit will
not stop but will continue in whatever state it was in until the time code signal is restored.
Mute Time Code Transmission Until Jammed
If the mute time code menu is set to ON the ZaxNet transmitter will not broadcast time code over ZaxNet
until the transmitter receives time code and jams its own internal time code generator. This prevents the
ZaxNet from sending incorrect time code to another device.
TIMECODE 23.98
GEN 09:18:05:02
TC SOURCE:
ZAXNET (RF)
TC JAM MODE:
AUTO-JAM NORMAL
MUTE TC SEND
UNTIL JAMED: OFF