Button Definition: 

Button 1 is used to call House Name 1 , Handsets with 001 code 
Button 2 is used to call House Name 2 , Handsets with 002 code 
 

Dip switches

 
Dip switch 1 & 2 are used to set the 

ID code

. ID code is used to avoid interference from other systems 

and to provide security with gate opening. There are 4 different ID codes to select 
 
Setting of ID code:   
Dip switch set in UP position = 1    DOWN position = 0  

 

 

 

       

 

 

 

 

 

 

 

Dip switch no.1   

 

  Dip switch no. 2 

 

ID code 1 

 

 

 

 

 

 

 

 

ID code 2 

 

 

 

 

 

 

 

 

ID code 3 

 

 

 

 

 

 

 

 

ID code 4 

 

 

 

 

 

 

 

 

 
Dip switch 3 & 4 are used to set the operating channel. The operating channel is the frequency setting 
and is used to avoid interference from other systems and to provide security with gate opening. Note that 
the operating channel must be the same as that of the handset. There are 4 operating channels 
 
Setting of operating channel:   

 

 

 

 

Dip switch set in UP position = 1    DOWN position = 0       
 

 

 

 

 

 

 

 

Dip switch no.3   

 

        Dip switch no.4   

CH1 

 

 

 

 

 

 

 

 

 

CH2 

 

 

 

 

 

 

 

 

 

CH3 

 

 

 

 

 

 

 

 

 

CH4 

 

 

 

 

 

 

 

 

 

             
 
 

Pairing procedures 

Each unique code/ house number needs to be programmed separately. If there are 2 or more handsets per 
button, they must be paired together at the same time from the gatestation. 
 
Pairing procedure 

1)

 

Handset into pairing mode 

2)

 

Gate station into pairing mode 

3)

 

Press pairing button on gatestation 

4)

 

Check code on handset 

5)

 

Reset handset battery and gatestation power and test communication   

 

 

  

 

 

 

 

Содержание ZA-614

Страница 1: ...tation including power supply relay board and external antenna ZA 613 Handsets with charger ZA 613 E Handsets with external antenna for maximum range and charger Note Gatestation are supplied separate...

Страница 2: ...ndant and is 100m in built up areas and 350m in more open areas The external antenna is mounted as high as possible for improved coverage and audio Note This Installers manual is intended to explain p...

Страница 3: ...n connected to 12v DC Use battery power for programming and range testing In case the gate station is not used for a long period of time it is recommended to disconnect the battery connector from the...

Страница 4: ...is the frequency setting and is used to avoid interference from other systems and to provide security with gate opening Note that the operating channel must be the same as that of the handset There ar...

Страница 5: ...d 7 sec the two Button LEDs will light up indicating the gate station has entered into pairing mode Now the PAIRING button can be released 4 Pairing Once both the handset handsets if more than one is...

Страница 6: ...low behind the structure The antenna mount uses a L bracket and includes plugs and screws Connect the cable at the back of gatestation to the antenna cable and ensure that the ends are fitted tightly...

Страница 7: ...igger B to isolate the gatestation from power surges etc The connection is different as the power wires to the relay should be connected in series with the trigger B contacts A standard receiver can a...

Страница 8: ...nting bracket to the gatestation and slide the bracket off the gatestation 1 The caller unit has been designed to be splash and rain proof Ensure that the rubber buttons and plate cover are fitted wel...

Страница 9: ...reliable operation even in harsh environment The unit meets to IP 54 standard and can operate from 30 C to 55 C Important terms OPERATING CHANNEL There are 4 channels to select from as there are 4 dif...

Отзывы: