Zartek CDP-808 Скачать руководство пользователя страница 8

Reset to factory/default setting 

           
Under standby mode, short circuit the two solder pads A & B for over 25 sec (with power supply 
connected), all programmed data will be erased and the unit returns to factory default setting. (i.e. PIN is 
111111). The gatestation can also be reset using the PC programming and clicking the “Return to factory 
settings” button 

 

 

   

 

 

                                                                                       

Range and External antenna 

The gatestation has been designed to be used with an external antenna. Typical range with the antenna 
mounted is 100m in built-up areas and 350m in more open areas. Heavily built up areas will affect the 
range significantly and possible reduce maximum range to less than 100m. Further range is always 
possible with higher placing of the antenna or by using the handset with external antenna. Place the 
external antenna in a vertical orientation on top of poles, walls or a roof. It is important to place the 
antenna away for metal or concrete. If the antenna must be placed against a wall or building, range will 
be good in front of the building but low behind the structure. The antenna mount uses a “L” bracket and 
includes plugs and screws.

 

Connect the cable at the back of gatestation to the antenna cable and ensure 

that the ends are fitted tightly. Extra 3m lengths of cable are available although it is advised not to 
exceed the length by 10m as power will be lost. 
 

Booster handset 

The ZA613 handset has an internal antenna and is therefore portable. Clarity and signal quality will be 
affected if there are many obstructions between the house and the gate such as trees, walls or buildings. 
It is then advisable to use a booster handset ZA613-E where a fixed external antenna with 6m of cable is 
permanently connected directly to the handset. Better audio and reception will be achieved by mounting 
the antenna outside the building and at some height so that there is clearer line-of-sight to the gate 
stations antenna.   
 
 
 
 

Содержание CDP-808

Страница 1: ...including power supply relay board and external antenna ZA 611 Back side Gate station including power supply relay board and external antenna ZA 612 Programming kits including cable and software ZA 61...

Страница 2: ...more open areas The external antenna is mounted as high as possible for improved coverage and audio Note This Installers manual is intended to explain programming and installation please refer to the...

Страница 3: ...anual programming is used to make small changes add new houses or program a few users Once the gatestation is programmed with names and unit numbers the handsets can be paired Manual Programming 1 Pre...

Страница 4: ...ng programming all residence names and house no press ENTER key to exit back to standby mode Note During programming if no key is pressed within 60 seconds the unit will automatically exit back to sta...

Страница 5: ...be paired together at the same time from the gatestation K6 Call alert select button K4 Lock A button K5 Lock B button K3 Call reply Calling gate station button K2 Hang Up Power ON OFF button K1 Hands...

Страница 6: ...tion successfully the selected house no will be shown in the LCD of handset Note If the selected house no is not a no that is previously programmed into the unit PAIRING will not be executed the word...

Страница 7: ...right icon The station is ready to use System busy function if required This function is used to block any communication from either front or back gatestation whilst another conversation is in progre...

Страница 8: ...roof It is important to place the antenna away for metal or concrete If the antenna must be placed against a wall or building range will be good in front of the building but low behind the structure T...

Страница 9: ...e controller board of a gate motor It is advisable to also use a relay board for trigger B to isolate the gatestation from power surges etc The connection is different as the power wires to the relay...

Страница 10: ...ate and then the 4 screws of the keypad bracket using the supplied special tool Gently remove the rubber keypad as shown in the figure below Unscrew the bolt holding the mounting bracket to the gatest...

Страница 11: ...eliable operation even in harsh environment The unit meets to IP 54 standard and can operate from 30 C to 55 C Important terms OPERATING CHANNEL There are 4 channels to select from as there are 4 diff...

Страница 12: ......

Отзывы: