Zartek CDP-808 Скачать руководство пользователя страница 7

             

 

Back gatestation 

It is possible to add an additional gatestation to be used on another entrance or exit, for instance to be 
notified when visitors want to exit. The functions of the back gatestation are similar to the front station 
as all the same names and codes are stored on the station. Gate triggering is limited in that a call has to 
be initiated from the back gatestation in order to be able to trigger the gate it is connected to. 
 
Programming a gatestation: 
Once the front gate has been programmed and all the handsets paired the front gate will be able to clone 
a backgate station. Note that if any changes are made to the front gate programming such as new names, 
numbers or additional handsets, the back gate will need to be updated again via PC cloning. 
 
Enter PC programming mode on both the front and back gate 
Connect the front gate to the PC using the cable and READ from gatestation (left icon). 
The PC will load all the programming on the screen 
Now connect the back gate station and WRITE to station (right icon) 
The station is ready to use. 
 
System busy function (if required) 
This function is used to block any communication from either front or back gatestation whilst another 
conversation is in progress. A hard wire connection is required between the 2 gatestations. There is a 3 
core wire coming from the back of each gate station, the colour of wires are red, white and black. Connect 
red to red, black to black and white to white. 
 
If you do not connect these wires, the gate station will still perform normally but will not have the system 
busy function. 
 
When either the front or back station is making call, the remaining station cannot make any calls until the 
station in use finishes the call. The screen of remaining station will show: 
“SYSTEM IN USE PLEASE WAIT” 
 
Above text will be shown until the station in use finishes the call. In case a visitor tries to make a call when 
this text is shown on screen, the station will just ignore the input and provide no response. 
When two visitors approach the front and gate station at same time and try to make a call, the visitor who 
first press the CALL button can initiate the call, the remaining station cannot make a call and screen will 
show “ SYSTEM IN USE   PLEASE WAIT” 

 
 
 
 
 
 
 
 
 

Содержание CDP-808

Страница 1: ...including power supply relay board and external antenna ZA 611 Back side Gate station including power supply relay board and external antenna ZA 612 Programming kits including cable and software ZA 61...

Страница 2: ...more open areas The external antenna is mounted as high as possible for improved coverage and audio Note This Installers manual is intended to explain programming and installation please refer to the...

Страница 3: ...anual programming is used to make small changes add new houses or program a few users Once the gatestation is programmed with names and unit numbers the handsets can be paired Manual Programming 1 Pre...

Страница 4: ...ng programming all residence names and house no press ENTER key to exit back to standby mode Note During programming if no key is pressed within 60 seconds the unit will automatically exit back to sta...

Страница 5: ...be paired together at the same time from the gatestation K6 Call alert select button K4 Lock A button K5 Lock B button K3 Call reply Calling gate station button K2 Hang Up Power ON OFF button K1 Hands...

Страница 6: ...tion successfully the selected house no will be shown in the LCD of handset Note If the selected house no is not a no that is previously programmed into the unit PAIRING will not be executed the word...

Страница 7: ...right icon The station is ready to use System busy function if required This function is used to block any communication from either front or back gatestation whilst another conversation is in progre...

Страница 8: ...roof It is important to place the antenna away for metal or concrete If the antenna must be placed against a wall or building range will be good in front of the building but low behind the structure T...

Страница 9: ...e controller board of a gate motor It is advisable to also use a relay board for trigger B to isolate the gatestation from power surges etc The connection is different as the power wires to the relay...

Страница 10: ...ate and then the 4 screws of the keypad bracket using the supplied special tool Gently remove the rubber keypad as shown in the figure below Unscrew the bolt holding the mounting bracket to the gatest...

Страница 11: ...eliable operation even in harsh environment The unit meets to IP 54 standard and can operate from 30 C to 55 C Important terms OPERATING CHANNEL There are 4 channels to select from as there are 4 diff...

Страница 12: ......

Отзывы: