4.2 CHOPPER CONFIGURATION AND CONNECTIONS DESCRIPTION
The choices made regarding power connections must be communicated to the chopper.
In order to supply this information, you have to connect the chopper to the programming
console and access the set model, set options, and adjustment menus (see specific con-
figuration descriptions).
- CONFIGURATION OF THE MODEL: SET MODEL MENU
Allows chopper to operate in one of the 3 possible modes.
1) REGENER. TR = regenerative traction
2) STANDARD PUMP = standard lifting
3) PUMP+HYDRO = lifting with hydrodrive contactor handling
- CONFIGURATION OF OPTIONS: SET OPTIONS MENU
function
option
meaning
BYPASS CONTACTOR
Bypass
Bypass contactor
Weakening cont
Weakening contactor.
SPEED CONTROL
On
No speed check.
Off
Speed check activated.
BATTERY CHECK
On
No low battery charge alarm.
Off
Low charge alarm with 50%
max. current if less than 10%
of charge.
ANTIROLLBACK
On
No Anti-rollback.
Off
Anti-rollback handled.
RELEASE BRAKING
On
No regenerative braking at
release.
Off
Release braking.
HOUR COUNTER
Running
Hour-meter active only when
running.
Key on
Hour-meter active with key on.
QUICK INVERSION
Off
E1 = Reduction of speed
no.3.
On
E1 = Rapid inversion input.
SAFETY SWITCH
Seat
E4 = Seat microswitch.
Handle
E4 = Handle microswitch.
BACKING FUNCTION
Off
E2 = Speed reduction no.2.
On
E2 = Back request with
speed relative to cutback
speed #2 and timing of back