Page - 18/18
ADBZP0AB - CAN TILLER - User Manual
7 PERIODIC MAINTENANCE TO BE
REPEATED AT TIMES INDICATED
Check the belly microswitch. Using a suitable test meter, confirm that there is no
electrical resistance between the contacts by measuring the volt drop between
the terminals. Switches should operate with a firm click sound. Microswitches
should be checked every ...................................................................... 3 MONTHS
Using the console tester menu check the functioning of all the digital and analog
inputs. Check every .............................................................................. 3 MONTHS
Checks should be carried out by qualified personnel only. The installation of this
electronic device should be made according to the diagrams included in this
Manual. Any variations or special requirements should be made after consulting
a Zapi Agent.
The supplier is not responsible for any problem that arises from wiring methods
that differs from information included in this Manual. During periodic checks, if a
technician finds any situation that could cause damage or compromise safety, the
matter should be bought to the attention of a Zapi Agent immediately. The Agent
will then take the decision regarding operational safety of the machine.
Remember that Battery Powered Machines feel no pain.
NEVER USE A VEHICLE WITH A FAULTY ELECTRONIC CONTROLLER.
U
IMPORTANT NOTE ABOUT WASTE MANAGEMENT:
This controller has both mechanical parts and high-density electronic parts
(printed circuit boards and integrated circuits). If not properly handled
during waste processing, this material may become a relevant source of
pollution. The disposal and recycling of this controller has to follow the
local laws for these types of waste materials.
Zapi commits itself to update its technology in order to reduce the
presence of polluting substances in its product.