Zapi ADPZP0CC Скачать руководство пользователя страница 12

Page - 12/36 

ADPZP0CC - MHYRIO FLASH CONTROLLER - User Manual 

So the analysis works in two directions: 
 
1)  The study of the 

emission

 problems, the disturbances generated by the 

device and the possible countermeasure to prevent the propagation of that 
energy; we talk about “conduction” issues when guiding structures such as 
wires and cables are involved, “radiated emissions” issues when it is studied 
the propagation of electromagnetic energy through the open space. In our 
case the origin of the disturbances can be found inside the controller with the 
switching of the mosfets which are working at high frequency and generate 
RF energy, 

but wires and cables have the key role to propagate the 

disturbs because they works as antennas

, so a good layout of the cables 

and their shielding can solve the majority of the emission problems. 

 
2)  The study of the 

immunity

 can be divided in two main branches: protection 

from electromagnetic fields and from electrostatic discharge. 
The 

electromagnetic immunity

 concern the susceptibility of the controller 

with regard to electromagnetic fields and their influence on the correct work 
made by the electronic device. 
There are well defined tests which the machine has to be exposed to. 
These tests are carried out at determined levels of electromagnetic fields, to 
simulate external undesired disturbances and verify the electronic devices 
response. 

 
3)  The second type of immunity, 

ESD

, concerns the prevention of the effects of 

electric current due to excessive electric charge stored in an object. In fact, 
when a charge is created on a material and it remains there, it becomes an 
“electrostatic charge”; ESD happens when there is a rapid transfer from a 
charged object to another. This rapid transfer has, in turn, two important 
effects: 
A)  this rapid charge transfer can determine, by induction, disturbs on the 

signal wiring and thus create malfunctions; 

this effect is particularly 

critical in modern machines, with serial communications (canbus) 
which are spread everywhere on the truck and which carry critical 
information.

 

B)  in the worst case and when the amount of charge is very high, the 

discharge process can determine failures in the electronic devices; the 
type of failure can vary from an intermittently malfunction to a completely 
failure of the electronic device. 

 

IMPORTANT NOTE

: it is always much easier and cheaper to avoid ESD from 

being generated, than to increase the level of immunity of the electronic devices. 
 
There are different solutions for EMC issues, depending on level of emissions/ 
immunity required, the type of controller, materials and position of the wires and 
electronic components. 
 
1) 

EMISSIONS

. Three ways can be followed to reduce the emissions:  

 

A)  SOURCE OF EMISSIONS: finding the main source of disturb and work 

on it. 

B)  SHIELDING: enclosing contactor and controller in a shielded box; using 

shielded cables;  

C)  LAYOUT: a good layout of the cables can minimize the antenna effect; 

cables running nearby the truck frame or in iron channels connected to 
truck frames is generally a suggested not expensive solution to reduce 

Содержание ADPZP0CC

Страница 1: ...STRIAL EQUIPMENTS CONSTRUCTION Via Parma 59 42028 POVIGLIO RE ITALY Tel 39 0522 960050 r a Fax 39 0522 960259 e mail zapi zapispa it web www zapispa it EN User Manual MHYRIO FLASH CONTROLLER MULTIFUNC...

Страница 2: ...make changes or improvements to its products at any time and without notice The present publication reflects the characteristics of the product described at the moment of distribution The publication...

Страница 3: ...nifit 4 poles 16 5 5 Connector CNE ZAPI Minifit 8 poles 16 5 6 Connector CNF ZAPI Minifit 10 poles 16 5 7 Connector CNG ZAPI Minifit 16 poles 17 6 DRAWINGS 18 6 1 Mechanical drawing 18 6 2 Functional...

Страница 4: ...DPZP0CC MHYRIO FLASH CONTROLLER User Manual APPROVAL SIGNS COMPANY FUNCTION INITIALS SIGN PROJECT MANAGER FG TECHNICAL ELECTRONIC MANAGER VISA PP SALES MANAGER VISA PN Publication N ADPZP0CC Edition O...

Страница 5: ...oday we use a more sophisticated and safe communication protocol CAN BUS In this way it is possible to reduce the harness allocating the modules exactly near the sensor or the actuators and connecting...

Страница 6: ...yrio Flash accepts two analog inputs The range have to be specified in the order 0 20 mA 0 5 V 0 10 V 0 VBatt 13 V 200 mA output is provided to supply potentiometer or similar device Encoder encoder e...

Страница 7: ...o failures misbehaviour bad performances 3 1 1 Connection cables For the auxiliary connections use cables of 0 5 mm section For the valves connections use cables of 0 75 mm section 3 1 2 Fuses Use a 6...

Страница 8: ...of the system to disturbances a good choice would be to use a cable with a shield connected to the frame of the truck Sometimes it is sufficient a simple double wire cable or a duplex cable not shiel...

Страница 9: ...n and a pump motor controller and a third module works with less current the best way to deal this configuration is to create a common ground point star configuration U Correct Layout Note Module 1 po...

Страница 10: ...can lead to short circuits and failure so before turning on the truck for the first time verify with a multimeter the continuity between the starting point and the end of a signal wire For information...

Страница 11: ...by feedbacking this output voltage to the C A D converter Furthermore it is possible to input a positive for valves independent by the Mhyrio Flash supply to input B6 It is strongly suggested that thi...

Страница 12: ...tion of the effects of electric current due to excessive electric charge stored in an object In fact when a charge is created on a material and it remains there it becomes an electrostatic charge ESD...

Страница 13: ...nded test grounding devices on a daily basis for correct functioning this precaution is particularly important during controller handling in the storing and installation phase B ISOLATION use anti sta...

Страница 14: ...one valve of the group can be active It is possible to activate more function at the same time These can be function 1 2 3 function 1 2 4 3 and 4 cannot be activate at the same time FUNCTION1 is relat...

Страница 15: ...ive of electrovalves safety A14 PEV Positive supply of digital input devices A15 PEV Positive supply of digital input devices A16 PEV Positive supply of digital input devices A17 PEV Positive supply o...

Страница 16: ...Serial communication interface E5 GND Negative supply E6 12 12V supply E7 BOOT Flash memory bootstrap E8 GND Flash memory bootstrap 5 6 Connector CNF ZAPI Minifit 10 poles F1 R Resistance F2 NEV3 Neg...

Страница 17: ...NEVP3 Negative of the proportional electrovalve N 3 G7 NEVP2 Negative of the proportional electrovalve N 2 G8 NEVP1 Negative of the proportional electrovalve N 1 G9 PEV Positive of the proportional el...

Страница 18: ...Page 18 36 ADPZP0CC MHYRIO FLASH CONTROLLER User Manual 6 DRAWINGS 6 1 Mechanical drawing...

Страница 19: ...ADPZP0CC MHYRIO FLASH CONTROLLER User Manual Page 19 36 6 2 Functional drawing...

Страница 20: ...nnector for console connection The Console must be connected to the console connector of another ZAPI product that communicates with MHYRIO FLASH via CAN BUS line U Pay attention to the polarity of th...

Страница 21: ...ADPZP0CC MHYRIO FLASH CONTROLLER User Manual Page 21 36 7 3 Description of standard console menu...

Страница 22: ...to ON OFF valve type OPTION 2 It sets EV5 to PROPORTIONAL valve type EV6 TYPE OPTION 1 It sets EV6 to ON OFF valve type OPTION 2 It sets EV6 to PROPORTIONAL valve type EV7 TYPE OPTION 1 It sets EV7 t...

Страница 23: ...go into the SET OPTIONS Menu 7 The display will shows the first option EV2 TYPE OPTION1 8 Press ROLL UP or ROLL DOWN buttons until desired option appears 9 Desired option appears EV1 TYPE OPTION1 10...

Страница 24: ...e 3 if it is set as proportional see set options menu 4 MIN EV4 This parameter adjusts the minimum current of valve 4 if it is set as proportional see set options menu 5 MIN EV5 This parameter adjusts...

Страница 25: ...ange from 0 A to operating current 20 GROUP1 DEC DELAY Lift lowering valves current deceleration delay this parameter sets the valve 1 and 2 closing ramp to change the coil current from operating curr...

Страница 26: ...ed parameter appears 7 The names of the Parameters appear on the Display MIN EV1 LEVEL 5 8 When the desired Parameter appears the Display will show a Level Number that will be between 0 and 9 Press ei...

Страница 27: ...UT 5 It indicates the state of the digital input 5 CNA4 Options ON active entry of closed switch equal to battery positive potential OFF inactive entry of open switch equal to GND potential 6 DIGITAL...

Страница 28: ...ial 17 STATUS 1 It indicates the state of the STATUS1 electrovalve CNF4 Options ON active entry of closed switch equal to battery positive potential OFF inactive entry of open switch equal to GND pote...

Страница 29: ...on the display 5 The Display shows TESTER MAIN MENU TESTER 6 Press ENTER to go into the TESTER function 7 The first variable to be tested is shown on the Display DIGITAL INPUT 1 ON 8 Press either ROL...

Страница 30: ...unction don t create problems to the console functionality and to the others ZAPI device functionality 7 9 Description of the console restore function The RESTORE PARAM function is allowed in MHYRIO F...

Страница 31: ...T MENU 3 The Display will show SET MODEL If another menu is displayed press ROLL UP or ROLL DOWN until SET MODEL appears CONFIG MENU SET MODEL 4 Press ENTER to go into the SET MODEL Menu 5 The display...

Страница 32: ...METER CONNECTED PRODUCT 1 SICOS 2 TRACTION CONTROLLER 5 PUMP CONTROLLER 6 EPS 9 MHYRIO FLASH The range for this parameter is 0 32 but only above number are enabled If operator selects a not specified...

Страница 33: ...000 2 Press ENTER to go into the General menu 3 The Display will show MAIN MENU PARAMETER CHANGE 4 Press ROLL UP or ROLL DOWN button until PARAMETER CHANGE appears on the display 5 The Display will sh...

Страница 34: ...eceive any message from the SICOS CAN BUS line First of all check the wiring If it is ok the problem is on the logic board which must be replaced 3 SHUNT VALVES There is a short across the valve coil...

Страница 35: ...art Number Description C12358 Minifit Connector 4 pins Female C12359 Minifit Connector 6 pins Female C12414 Minifit Connector 8 pins Female C12500 Minifit Connector 10 pins Female C12404 Minifit Conne...

Страница 36: ...eir full or programmed level Check every 3 MONTHS Check the mechanical operation of the Contactor s Moving contacts should be free to move without restriction Check every 3 MONTHS Checks should be car...

Отзывы: