AF2ZP0CL - ACE2 - User Manual
Page - 71/85
Safety out
The Safety-out
driver is damaged
(shorted or open)
MC is not closed,
EB is applied,
Traction/Pump
stopped
Start-up
Traction/Pump
request
Watchdog#1
MDI code allarm
8
The watchdog
signal #1 is not in
the correct status
MC is opened,
EB is applied,
Traction/Pump
stopped
Start-up, stand-by,
running
Key re-cycle
Watchdog#2
MDI code allarm
8
The watchdog
signal #2 is not in
the correct status
MC is opened,
EB is applied,
Traction/Pump
stopped
Start-up, stand-by,
running
Key re-cycle
Keyoff shorted
MDI code allarm
76
At Start-up the Key-
off
logic signal is low
MC is not closed,
EB is applied,
Traction/Pump
stopped
Start-up Key
re-cycle
Logic Failure#1
MDI code allarm
54
An undervoltage /
overvoltage
condition has been
detected
MC is not closed,
EB is applied,
Traction/Pump
stopped
Start-up, stand-by,
running
Traction/Pump
request
Logic failure #3
MDI code allarm
17
High current HW
protection circuit is
damaged
MC is not closed,
EB is applied,
Traction/Pump
stopped
Start-up
Traction/Pump
request
Power mos shorted
MDI code allarm
89
Short circuit on the
power Mosfets
MC is not closed,
EB is applied,
Traction/Pump
stopped
Start-up
Traction/Pump
request
Vmn high
Motor output
voltage higher than
expected
MC is not closed,
EB is applied,
Traction/Pump
stopped
Start-up,
Stand-by
Traction/Pump
request
Vmn low
MDI code allarm
72
Motor output
voltage lower than
expected
MC is opened,
EB is applied,
Traction/Pump
stopped
Start-up, running
Traction/Pump
request
Stby I high
MDI code allarm
53
In stby condition
(no current applied
to the motor) the
current feedbacks
are out of permitted
stby range
MC is not closed,
EB is applied,
Traction/Pump
stopped
Start-up
Traction/Pump
request
Wrong 0 voltage
MDI code allarm
53
The motor phases
voltage feedback
are out of permitted
range
MC is not closed,
EB is applied,
Traction/Pump
stopped
Start-up Traction/Pump
Request
Contactor closed
MDI code allarm
75
LC contact is stuck
MC is not closed
(command is not
activated),
EB is applied,
Traction/Pump
stopped
Start-up Traction/Pump
Request
Содержание ACE2
Страница 7: ...AF2ZP0CL ACE2 User Manual Page 7 85 2 3Block diagram...
Страница 28: ...Page 28 85 AF2ZP0CL ACE2 User Manual 7 3Connection drawing Traction configuration...
Страница 29: ...AF2ZP0CL ACE2 User Manual Page 29 85 7 4Connection drawing Pump configuration...
Страница 30: ...Page 30 85 AF2ZP0CL ACE2 User Manual 7 5Connection drawing Combi configuration...
Страница 32: ...Page 32 85 AF2ZP0CL ACE2 User Manual 8 3Description of Standard Console Menu 8 3 1 Traction configuration...
Страница 33: ...AF2ZP0CL ACE2 User Manual Page 33 85 8 3 2 Pump configuration...