Page - 64/85
AF2ZP0CL - ACE2 - User Manual
8.11 Description of Console “RESTORE” function
The RESTORE PARAM function allows transfer of the Console’s stored data into
the memory of the inverter. This is achieved in a fast and easy way using the
method previously used with the SAVE PARAM. function.
The data that is available via the RESTORE PARAM. function is as follows:
-
All Parameter Values (PARAMETER CHANGE).
-
Options (SET OPTIONS).
-
The level of the Battery (ADJUST BATTERY).
U
ATTENTION: When the RESTORE operation is made, all data in the inverter
memory will be written over and replace with data being restored.
Flow Chart showing how to use the RESTORE function of the Digital Console.
1) Opening Zapi Display.
AE2T2B ZP0.12
24V 400A 00000
2) Press ENTER to go into the General menu.
' % '
' ' '
3) The Display will show:
MAIN MENU
PARAMETER CHANGE
4) Press ROLL UP or ROLL DOWN button until
RESTORE PARAM. appears on the Display.
% ' '
% ' '
5) The Display will show:
MAIN MENU
RESTORE PARAM.
6) Press ENTER to go into the RESTORE PARAM.
Function.
' % '
' ' '
7) The Display shows the type of Model stored,
with a Code Number.
SELECT : MOD. 00
AE2T ZAPI V1
8) Keep pressing either ROLL UP and ROLL
DOWN buttons until the desired model appears on
the Display.
% ' '
% ' '
SELECT : MOD. 01
AE2T ZAPI V1
9) Press ENTER to commence the Restore
operation.
' % '
' ' '
10) The Display will ask “ARE YOU SURE?”.
ARE YOU SURE?
YES=ENTER NO=OUT
11) Press ENTER for YES, or OUT for No.
' % '
' ' '
' ' '
' % '
Содержание ACE2
Страница 7: ...AF2ZP0CL ACE2 User Manual Page 7 85 2 3Block diagram...
Страница 28: ...Page 28 85 AF2ZP0CL ACE2 User Manual 7 3Connection drawing Traction configuration...
Страница 29: ...AF2ZP0CL ACE2 User Manual Page 29 85 7 4Connection drawing Pump configuration...
Страница 30: ...Page 30 85 AF2ZP0CL ACE2 User Manual 7 5Connection drawing Combi configuration...
Страница 32: ...Page 32 85 AF2ZP0CL ACE2 User Manual 8 3Description of Standard Console Menu 8 3 1 Traction configuration...
Страница 33: ...AF2ZP0CL ACE2 User Manual Page 33 85 8 3 2 Pump configuration...