Safety instructions
Warning! This must be read!
The laws, ordinances, directives and standards
in force in the country of use are to be followed
(safety regulations, proper recycling in accord-
ance with the regulations, etc.)
Installation may only be carried out by a quali-
fied electrician.
The minimum distances to other appliances
and units are to be observed.
Anti-shock protection must be provided by the
installation, for example drawers may only be
installed with a protective floor directly under-
neath the appliance.
The cut surfaces of the worktop are to be pro-
tected against moisture using a suitable seal-
ant.
The sealant seals the appliance to the work top
with no gap.
Do not use silicon sealant between the appli-
ance and the work top.
Avoid installing the appliance next to doors and
under windows. Otherwise hot cookware may
be knocked off the rings when doors and win-
dows are opened.
z
Risk of injury from electrical current.
•
The electrical mains terminal is live.
•
Make electrical mains terminal free of volt-
age.
•
Follow connection schematic.
•
Observe electrical safety rules.
•
Ensure anti-shock protection by installing
correctly.
•
The appliance must be connected to the
electrical supply by a qualified electrician.
z
Risk of injury from electrical current.
•
Loose and inappropriate plug and socket
connections can make the terminal overheat.
•
Have the clamping connections correctly in-
stalled by a qualified electrician.
•
Use strain relief clamp on cable.
•
In the event of single-phase or two-phase
connection, the appropriate mains cable of
type H05BB-F Tmax 90°C(or higher) or an
equivalent type must be used.
•
If this appliance’s mains cable is damaged, it
must be replaced by a special cable (type
H05BB-F Tmax 90°C; or higher) or an equiv-
alent type. The latter is available from the
Customer Care Department.
A device must be provided in the electrical in-
stallation which allows the appliance to be dis-
connected from the mains at all poles with a
contact opening width of at least 3 mm.
Suitable isolation devices include line protect-
ing cut-outs, fuses (screw type fuses are to be
removed from the holder), earth leakage trips
and contactors.