18
electrolux
18
Technical data
Heating element ratings
Bottom heating element
1000 W
Top heating element
800 W
Full oven (Top+Bottom)
1800 W
Grill
1650 W
Fan cooking
1825 W
Oven fan
25 W
Oven light
25 W
Cooling Fan
25 W
Total rating
1875 W
Operating voltage (50 Hz)
230 V
Dimensions of the recess
Height
under top
mm 593
in column
mm 580
Width
mm 560
Depth
mm 550
Oven
Height
mm 335
Width
mm 405
Depth
mm 400
Oven capacity
56 l
Instructions for the Installer
Installation and connection must be
done in compliance with the
regulations in force. Any
interventions must be carried out
when the appliance is switched off.
Only accredited engineers may work
on the appliance.
The manufacturer disclaims any
liability if the safety measures are not
observed.
Connecting to the electrical supply
Before connecting to the electrical supply, please
make sure:
- The fuse and the domestic electrical installation
must be designed for the max. load of the
appliance (see rating plate).
- The domestic electrical installation must be
equipped with a proper earth connection in
accordance with the regulations in force.
- The socket or the multi-pole off switch must be
easy to access after the appliance has been
installed.
The appliance is supplied without an electric sup-
ply cable,therefore you will have to fit to it a supply
cable with standardplug, suitable to the total elec-
tric load shown on the ratingplate. The plug is to
be inserted into a suitable wall socket.
If you require a direct connection to the electric
network (mains), it will be necessary to fit between
the appliance and the mains an omnipole switch,
with a minimum gap between contacts of 3 mm,
suitable for the required load and in compliance
with rules in force. The green & yellow ground
wire must not be interrupted by the switch, and
should be 2-3 cm longer than the phase and
neutral wires. The supply cable must in all cases
be laid out in such a way as to ensure that it does
not reach at any given point a temperature 50°C
higher than the ambient temperature.
Suitable power supply cables are the following
types, considering the respective necessary
section of cable: H07 RN-F, H05 RN-F, H05 RR-
F, H05 VV-F, H05 V2V2-F (T90), H05 BB-F.
Содержание ZOB 231
Страница 1: ...ZOB 231 User information Built in oven ...
Страница 22: ...22 electrolux 22 ...
Страница 24: ...24 electrolux 24 35695 7401 06 07R 0 GRAFICHE MDM Forlì ...