MAINTENANCE

Grease filters

CLEANING METAL SELF-SUPPORTING GREASE FILTERS

Activated charcoal filter (Recirculation version)

REPLACING THE ACTIVATED CHARCOAL FILTER

The filters must be cleaned when led S4 starts to
flash or at least once every two months of opera-
tion, or more frequently with heavy usage, and can
be washed in a dishwasher. 

Resetting the alarm signal
• Press button R, using a sharp object (for example 

the tip of a pencil).

• The Alarm indicator led S4 will go out.

Cleaning the filters
• Remove the filters one at a time by pushing 

them towards the back of the group and pulling 
down at the same time.

• Wash the filters, taking care not to bend them. 

Allow them to dry before refitting.

• When refitting the filters, make sure that the 

handle is visible on the outside.

This filter is not washable and cannot be regener-
ated, and must be replaced when led S5 starts to
flash, or at least once every four months of opera-
tion. The Alarm is only signalled when the Recircu-
lation motor is turned on. 

Resetting the alarm signal
• Press button R, using a sharp object (for example 

the tip of a pencil).

• The Alarm indicator led S5 will go out.

Replacing the filter
• Remove the metal grease filters
• Remove the saturated activated carbon filter by 

releasing the fixing hooks

• Fit the new filter by hooking it into its housing
• Replace the metal grease filters.

Содержание ZHC 927

Страница 1: ...kap ZHC 927 MANUALE DI INSTALLAZIONE USO E MANUTENZIONE INSTALLATION USE AND MAINTENANCE HANDBOOK MANUEL D INSTRUCTIONS POUR L INSTALLATION L EMPLOI ET L ENTRETIEN HANDBUCH FÜR INSTALLATION BEDIENUNG UND WARTUNG INSTRUCTIES VOOR MONTAGE GEBRUIK EN ONDERHOUD ...

Страница 2: ...ations contained in this Instruction Manual your appliance will give you constant high performance and will remain efficient for many years to come CONTENTS RECOMMENDATIONS AND SUGGESTIONS 13 CHARACTERISTICS 14 INSTALLATION 15 USE 19 MAINTENANCE 20 ...

Страница 3: ...f aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben designed Never leave high nak...

Страница 4: ...9 1 Reducer Flange ø 150 120 mm 14 1 Hood Body Air Outlet Extension Piece consisting of two Half Shells 14 1 1 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs 12a 6 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 6 5 Q ty Documentation 1 Instruction Manual 1 Warranty 300 500 265 898 68 740 740 min 950 ma...

Страница 5: ...all at the centres of the holes in the bracket Place bracket 7 2 1 on the wall as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point on the horizontal reference line as indicated 116 mm from the vertical reference line Repeat this operat...

Страница 6: ...l on the base inserting the lower plate between the upper surface and the wall centring it on the vertical reference line Mark the centres of the two holes in the upper plate Drill ø 8 mm holes at all the centre points marked Insert the wall plugs 11 in the holes Position the top Profile 20 so that it rests against the top edge of the Back panel making sure that the screw holes coincide Fix the Ba...

Страница 7: ...hood body extension piece 14 Push fit the assembled hood body extension piece14 onto the air outlet Push fit connection 15 onto the hood body extension piece 14 Insert the connection extension pieces laterally 14 1 in connection 15 Make sure that the outlet of the extension pieces 14 1 is horizontally and vertically aligned with the chimney outlets If this is not the case adjust the position by ei...

Страница 8: ...e two sides of the flue and hook them between the upper flue and the wall making sure that they are well seated Fixthelowerpartlaterallytothehoodbodyusing the 2 screws 12c 2 9 x 6 5 supplied On the recirculation version fit the directional grids 8a 8b in their housings making sure that the directional symbols are towards the top and front of the hood Also make sure that they are correctly inserted...

Страница 9: ...ned off V5 Intensive speed Maximum speed used to eliminate the highest levels of cooking vapour emission Returns to Optimum speed automatically after it has been in operation for 15 minutes Intensive speed can also be turned off manually by pressing button V4 T Delayed shutdown This device allows any residual odours to be removed without having to wait and turn the appliance off as the Motor and L...

Страница 10: ... the group and pulling down at the same time Wash the filters taking care not to bend them Allow them to dry before refitting When refitting the filters make sure that the handle is visible on the outside This filter is not washable and cannot be regener ated and must be replaced when led S5 starts to flash or at least once every four months of opera tion TheAlarmisonlysignalledwhentheRecircu lati...

Страница 11: ...e Lighting support and pull it out of from the Hood Extract the Lamp from the Support Replace with another of the same type making sure that the two pins are properly inserted in the lamp holder socket holes Replace the Support fixing it in place with the two Screws removed as above ...

Страница 12: ...conforme à la norme européenne sur la basse tension C E E 73 23 relati ve à la sécurité électrique et aux normes européennes C E E 89 336 relative à la compatibilité électromagnétique et C E E 93 68 relative au marquage CE Dieses Gerät entspricht den europäischen Niederspannungsrichtlinien 73 23 EWG zur elektrischen Sicherheit den europäischen Richtlinien 89 336 EWG zur elektromagnetischen Verträg...

Отзывы: