REPLACEMENT OF THE CONNECTION
CABLE
The replacement of electric cable must
be carried out exclusively by the
service force centre or by personnel
with similar competencies, in
accordance with the current
regulations.
To replace the connection cable use
only H03V2V2-F T90 or equivalent
type. Make sure that the cable section
is applicable to the voltage load and
the working temperature. The yellow/
green earth wire (B) must be
approximately 2 cm longer than the live
and neutral wire (A).
A
B
1. Connect the green and yellow (earth) wire to
the terminal which is marked with the letter 'E',
or the earth symbol , or coloured green and
yellow.
2. Connect the blue (neutral) wire to the terminal
which is marked with the letter 'N' or coloured
blue.
3. Connect the brown (live) wire to the terminal
which is marked with the letter 'L'. It must
always be connected to the network phase.
There must be no cut or stray strands of wire
present. The cord clamp must be correctly
attached to the outer sheath.
ASSEMBLY
1.
2.
3.
min. 55 mm
min. 650 mm
560 mm
2
0
+
min. 100 mm
30 mm
480 mm
2
0
+
min. 600 mm
4.
50 mm
400 mm
9