Zanussi ZGL62I Скачать руководство пользователя страница 11

By-pass diameters

Burner

Ø By-pass in 1/100 mm.

Auxiliary

28

Burner

Ø By-pass in 1/100 mm.

Semi-rapid

32

Rapid

42

Gas burners

BURNER

NORMAL

POWER

REDUCED

POWER

NORMAL POWER

NATURAL GAS

G20 (2H) 20 mbar

LPG

(Butane/Propane) G30/G31 (3+)

28-30/37 mbar

kW

kW

inj. 1/100

mm

m³/h

inj. 1/100

mm

g/h

g/h

G30

G31

Auxiliary

burner

1.0

0.33

70

0.095

50

73

71

Semi-rapid

burner

2.0

0.45

96

0.190

71

145

143

Rapid burn-

er

3.0 (nat. gas)

2.8 (LPG)

0.75

119

0.286

86

204

200

Environment concerns

The symbol   on the product or on its packaging

indicates that this product may not be treated as

household waste. Instead it should be taken to the

appropriate collection point for the recycling of electrical

and electronic equipment. By ensuring this product is

disposed of correctly, you will help prevent potential

negative consequences for the environment and human

health, which could otherwise be caused by inappropriate

waste handling of this product. For more detailed

information about recycling of this product, please contact

your local council, your household waste disposal service

or the shop where you purchased the product.

Packaging material

The packaging materials are friendly to the environ-

ment and can be recycled. The plastic components

are identified by marking: >PE<,>PS<, etc. Discard the

packaging materials as household waste at the waste dis-

posal facilities in your municipality.

 

11

Содержание ZGL62I

Страница 1: ...EN User manual Gas hob ZGL62I GB ...

Страница 2: ...yer of the stainless steel hob panel if present from the ap pliance before first use Do not remove the rating plate It can invalidate the guarantee Set the cooking zones to the off position after each use Burners and accessible part become hot during and af ter use Do not put cutlery or saucepan lids on the cooking surface Cookware and its contents can tip over There is the risk of burns Too hot f...

Страница 3: ...n prod ucts evacuation device It must be installed and con nected in accordance with current installation regula tions Particular attention must be given to the relevant requirements regarding ventilation The use of a gas cooking appliance cause heat and moisture in the room in which it is installed Make sure that the ventilation in the kitchen is good keep natural ventilation holes open or instal...

Страница 4: ... volume greater than 20 m but not in a bathroom or shower room The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 400 mm If it is fitted below 400 mm a space of 50 mm must be allowed from the edges of the hob For appliances installed in the Republic of Ireland please refer to NSAI Domestic Gas Installation I S 813 Current Edition Section 7 Pe...

Страница 5: ...qualified electrician or competent person in accordance with the current regulations THIS HOB MUST BE EARTHED Always use a correctly installed shockproof socket Make sure that there is an access to the mains plug af ter installation Do not pull the mains cable to disconnect the appli ance Always pull the mains plug The appliance must not be connected with an extension cable an adapter or a multipl...

Страница 6: ...ust be no cut or stray strands of wire present and the cord clamp must be secure over the outer sheath Important A cut off plug inserted into a 13 amp socket is a serious safety shock hazard Ensure that the cut off plug is disposed of safely Important The replacement of electric cable must be carried out exclusively by the service force centre or by personnel with similar competencies in accordanc...

Страница 7: ... with vents to let a con tinuous supply of air The electrical connection of the hob and the oven must be installed separately for safety rea sons and to let easy remove oven from the unit 50 cm2 360 cm2 180 cm2 120 cm2 MANUFACTURER ELECTROLUX ITALIA S p A C so Lino Zanussi 30 33080 PORCIA PN ITALIA Product description Cooking surface layout 2 1 5 4 3 1 Semi rapid burner 2 Semi rapid burner 3 Contr...

Страница 8: ...ly when you switch on the mains after installation or a pow er cut It is normal Turning the burner off To put the flame out turn the knob to the symbol Warning Always turn the flame down or switch it off before you remove the pans of the burner Helpful hints and tips Energy savings If possible always put the lids on the pans When the liquid starts to boil turn down the flame to barely simmer the l...

Страница 9: ...fer to this you must not cook with potstones earthenware pans or cast iron plates Do not use alumini um foil to prevent damage the top during operation Cleaning of the spark plug This feature is obtained through a ceramic ignition candle with a metal electrode Keep these components well clean to prevent difficult lighting and check that the burner crown holes are not obstructed Periodic maintenanc...

Страница 10: ...ta are available on the identification plate from the injectors kit Model description Product number PNC Serial Number S N Use the original spare parts only They are available at Service Force Centre and approved spare parts shops Technical data Hob dimensions Width 580 mm Length 500 mm Hob recess dimensions Width 550 mm Length 470 mm Heat input Rapid burner 3 0 kW Semi rapid burner 2 0 kW Auxilia...

Страница 11: ...stead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product...

Страница 12: ...www zanussi com shop 397193201 A 362010 ...

Отзывы: