• Make sure that there is an access to the mains
plug after the installation.
• Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
• There is a risk of fire when the appliance is in
connection with an extension cable, an adapter
or a multiple connection. Make sure that the
ground connection agrees with the standards
and regulations.
• Do not let the power cable to heat up to a
temperature higher than 90° C.
Make sure that you connect the blue
neutral cable to the terminal with a
letter "N" on it. Connect the brown (or
black) phase cable to the terminal
which has a letter "L". Keep the phase
cable connected at all times.
CONNECTION CABLE
To replace the connection cable use only the
special cable or its equivalent. The cable type is:
H05V2V2-FT90.
Make sure that the cable section is applicable to
the voltage and the working temperature. The
yellow / green earth wire must be approximately 2
cm longer than the brown (or black) phase wire.
ASSEMBLY
1.
2.
3.
min. 55 mm
min. 650 mm
560 mm
min. 450 mm
30 mm
480 mm
4.
5.
6.
B
A
A) supplied seal
B) supplied brackets